Agilent manuals, page 238
Agilent Optimizing Vial Pressurization Parameters for the Analysis of USP 467 Residual Solvents Using the 7697A Headspace Sampler
Agilent Fast Refinery Gas Analysis Using the 490-GC Micro-GC QUAD
Application Note 6 pages · 953 KB · ENThis application note describes the use of the Agilent 490 Micro GC QUAD for fast and accurate analysis of refinery gases, achieving results in about two…
Agilent 1290 Infinity LC Method Development System Application Note
Application Note 8 pages · 564 KB · ENThis application note describes developing a UHPLC method for analyzing amines derived from banned azo dyes using the Agilent 1290 Infinity LC system and…
Agilent 1290 Infinity LC Application Note: High Sensitivity UHPLC-DAD Analysis of Azo Dyes
Application Note 8 pages · 737 KB · ENThis application note details the analysis of toxic aromatic amines from azo dyes using the Agilent 1290 Infinity LC System with the Max-Light high…
Agilent ZORBAX RRHD 300SB-C18 1.8 um Application Note
Application Note 4 pages · 377 KB · ENThis application note demonstrates the fast separation of recombinant human erythropoietin using the Agilent ZORBAX RRHD 300SB-C18 1.8 um column.
Scalability of Agilent Columns Across HPLC and UHPLC Instruments Application Note
Application Note 10 pages · 1.4 MB · ENThis application note demonstrates the scalability of Agilent ZORBAX columns across different HPLC and UHPLC instrument configurations.
Purification of antibodies using the Agilent AssayMAP Bravo platform Application Note
Application Note 4 pages · 269 KB · ENThis application note describes the purification of poly- and monoclonal antibodies from cell culture supernatants using the Agilent AssayMAP Bravo platform…
Agilent Analysis of Ascorbic Acid Citric Acid Benzoic Acid in Orange Juice Application Solution
Application Note 2 pages · 962 KB · ENThis application note describes a method to quantify antioxidants and preservatives in orange juice using Agilent 1260 Infinity and 1290 Infinity LC systems.
Agilent 490 Micro GC Application Note for Acetone, Methanol, and Ethanol Analysis in Air
Application Note 2 pages · 152 KB · ENThis application note describes the analysis of acetone, methanol, and ethanol in air using the Agilent 490 Micro GC with a CP-Wax 52 CB column channel.
The Influence of Silica Pore Size and Particle Size on Insulin Separation Application Note
Application Note 8 pages · 742 KB · ENThis application note evaluates the effect of silica pore size (80A to 300A) and particle size (1.8 µm to 5 µm) on the HPLC separation efficiency and…
Agilent Fast Analysis of Zanthoxylum nitidum Using Agilent Poroshell 120 EC-18 Columns
Application Note 4 pages · 265 KB · ENThis application note describes a fast HPLC method for analyzing nitidine chloride in Zanthoxylum nitidum using Agilent Poroshell 120 EC-C18 columns.
Agilent MassHunter Study Manager Application Note
Application Note 8 pages · 899 KB · ENThis application note describes how Agilent MassHunter Study Manager automates LC/MS workflows for drug metabolism and pharmacokinetics studies.
Agilent RapidFire/MS Systems Analysis of Acetyl-Coenzyme A Carboxylase Application Note
Application Note 4 pages · 173 KB · ENThis application note demonstrates the use of Agilent RapidFire/MS Systems for high-throughput screening of the Acetyl-Coenzyme A Carboxylase (ACC) target.
Agilent RapidFire/MS Systems Application Note: Analysis of LpxC
Application Note 4 pages · 182 KB · ENThis application note demonstrates the use of Agilent RapidFire/MS Systems for high-throughput screening of the LpxC enzyme using native substrates.
Agilent 6460 Triple Quadrupole LC/MS System Application Note
Application Note 4 pages · 128 KB · ENThis application note describes the successful transfer of an LC/MS/MS method for bupropion analysis from a Shimadzu system to an Agilent 6460 Triple…
