Yaskawa PG-F3 Manuals

ManualLib has 2 documents for the Yaskawa PG-F3 (Other Electronics): 2 installation guides. Every file can be read online or downloaded as a PDF for free.

Installation Guide 2

Key facts

Brand
YASKAWA
Model
PG-F3
Industry
Industrial
Documents
2
Languages
EN
Last added
2026-11-22

Start here

Yaskawa PG-F3 Motor Encoder Feedback (EnDat, HIPERFACE) Interface Installation Manual

Yaskawa PG-F3 Motor Encoder Feedback (EnDat, HIPERFACE) Interface Installation Manual

Installation Guide 61 pages · 6.3 MB · EN

The PG-F3 option allows the user to connect certain rotary encoders to applicable Yaskawa drives. Suitable rotary encoders include EnDat 2.1/01, EnDat 2.2/01, or EnDat 2.2/22 by HEIDENHAIN, or HIPERFACE by SICK STEGMANN. It facilitates motor speed feedback to the drive and supports PM Closed Loop Vector control. The option reads a 20 kHz maximum input frequency from the PG encoder.

The manual covers receiving, option components, installation procedure, related parameters, troubleshooting, European standards, specifications, and disposal. It also lists compatible drive series and the tools needed for installation.

Read online

Yaskawa PG-F3 specifications

Maximum input frequency20 kHz
Compatible encoder interfacesEnDat 2.1/01, EnDat 2.2/01, EnDat 2.2/22, HIPERFACE
Compatible drive seriesA1000, L1000A, U1000, U1000L, GA700, GA800, LA700

Source: Yaskawa PG-F3 Motor Encoder Feedback (EnDat, HIPERFACE) Interface Installation Manual

All Yaskawa PG-F3 documents by type

Installation Guide 2

Mounting, wiring and first power-up. Read it before the hardware goes in.

Questions answered in these manuals

Which rotary encoders can be connected with the PG-F3 option?

EnDat 2.1/01, EnDat 2.2/01, or EnDat 2.2/22 by HEIDENHAIN, or HIPERFACE by SICK STEGMANN.

From: Yaskawa PG-F3 Motor Encoder Feedback (EnDat, HIPERFACE) Interface Installation Manual

What is the maximum input frequency of the PG-F3 option?

The option reads a 20 kHz maximum input frequency from the PG encoder.

From: Yaskawa PG-F3 Motor Encoder Feedback (EnDat, HIPERFACE) Interface Installation Manual

Which encoders does the PG-F3 option card support?

The PG-F3 uses HEIDENHAIN rotary encoders EnDat2.1/01 and EnDat2.2/01.

From: YASKAWA PG-F3 AC Drive Option Card Installation Manual

What is the maximum input frequency of the PG-F3?

The PG-F3 has a maximum input frequency of 50 kHz, and the input frequency must not exceed 50 kHz during operation.