Yaskawa PG-F3 Motor Encoder Feedback (EnDat, HIPERFACE) Interface Installation Manual
The PG-F3 option allows the user to connect certain rotary encoders to applicable Yaskawa drives. Suitable rotary encoders include EnDat 2.1/01, EnDat 2.2/01, or EnDat 2.2/22 by HEIDENHAIN, or HIPERFACE by SICK STEGMANN. It facilitates motor speed feedback to the drive and supports PM Closed Loop Vector control. The option reads a 20 kHz maximum input frequency from the PG encoder.
The manual covers receiving, option components, installation procedure, related parameters, troubleshooting, European standards, specifications, and disposal. It also lists compatible drive series and the tools needed for installation.
Yaskawa PG-F3 specifications
| Maximum input frequency | 20 kHz |
|---|---|
| Compatible encoder interfaces | EnDat 2.1/01, EnDat 2.2/01, EnDat 2.2/22, HIPERFACE |
| Compatible drive series | A1000, L1000A, U1000, U1000L, GA700, GA800, LA700 |
Source: Yaskawa PG-F3 Motor Encoder Feedback (EnDat, HIPERFACE) Interface Installation Manual
All Yaskawa PG-F3 documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
Which rotary encoders can be connected with the PG-F3 option?
EnDat 2.1/01, EnDat 2.2/01, or EnDat 2.2/22 by HEIDENHAIN, or HIPERFACE by SICK STEGMANN.
From: Yaskawa PG-F3 Motor Encoder Feedback (EnDat, HIPERFACE) Interface Installation Manual
What is the maximum input frequency of the PG-F3 option?
The option reads a 20 kHz maximum input frequency from the PG encoder.
From: Yaskawa PG-F3 Motor Encoder Feedback (EnDat, HIPERFACE) Interface Installation Manual
Which encoders does the PG-F3 option card support?
The PG-F3 uses HEIDENHAIN rotary encoders EnDat2.1/01 and EnDat2.2/01.
From: YASKAWA PG-F3 AC Drive Option Card Installation Manual
What is the maximum input frequency of the PG-F3?
The PG-F3 has a maximum input frequency of 50 kHz, and the input frequency must not exceed 50 kHz during operation.
From: YASKAWA PG-F3 AC Drive Option Card Installation Manual