Key facts
- Brand
- YASKAWA
- Model
- SI-N3
- Category
- Industrial Robot
- Documents
- 2
- Languages
- EN
- Last added
- 2026-11-01
Start here

Yaskawa V1000 Option SI-N3/V DeviceNet Technical Manual
This manual provides detailed instructions for installing, configuring, and troubleshooting the DeviceNet communication option for the Yaskawa AC Drive-V1000. It covers components, wiring, parameter settings, and fault diagnosis. The option enables integration with DeviceNet networks for data exchange and remote control. Safety precautions and installation guidelines are included to ensure proper operation and prevent damage.
The manual is intended for technicians and engineers who need to configure the DeviceNet option with compatible Yaskawa drive models. It includes diagrams, component descriptions, and troubleshooting steps. Safety warnings are highlighted to prevent injury or equipment damage during installation or operation.
Yaskawa SI-N3 specifications
| Supported Messages | Group 2 Server (UCMM capable), Explicit Messages, Polled I/O Messages, Faulted Node Recovery |
|---|---|
| Input Power | 11Vdc-25Vdc |
| Current | 40mA |
| Ambient Temperature | -10°C to +50°C |
| Communications Speed | 125/250/500 kbps |
Source: Yaskawa SI-N3 AC Drive Option DeviceNet Installation Manual
All Yaskawa SI-N3 documents by type
Disassembly, diagnostics and part numbers, for repair.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What is the purpose of the DeviceNet Option SI-N3/V?
It provides a communications connection between the drive and an ODV A DeviceNet network, enabling data exchange and remote control.
From: Yaskawa V1000 Option SI-N3/V DeviceNet Technical Manual
What is the DeviceNet Option SI-N3/V used for?
It provides a communications connection between the drive and an ODV A DeviceNet network.
From: Yaskawa V1000 Option SI-N3/V DeviceNet Technical Manual
What drives are compatible with the SI-N3 option?
The option is compatible with A1000, E1000, H1000, L1000A, U1000, Z1000U, GA500, GA700, GA800, FP605, and GA500 drives.
From: Yaskawa SI-N3 AC Drive Option DeviceNet Installation Manual
Is a mounting kit required for the GA500 drive?
Yes, an option card mounting kit (model JOHB-GA50) is necessary to install the option on a GA500 drive.