Winsen ZH03B Laser Dust Sensor User Manual
The Winsen ZH03B is a compact, general-purpose laser dust sensor module that utilizes the Mie scattering principle to detect airborne dust particles. It features UART and PWM output capabilities, making it suitable for integration into air purifiers, new air systems, and air quality monitoring devices. The sensor offers good consistency and stability with a minimum detectable particle diameter of 0.3μm. This manual is written in Chinese.
Read onlineWinsen ZH03B specifications
| Minimum Resolvable Particle Diameter | 0.3μm |
|---|---|
| Operating Voltage | 5V±0.1V |
| Working Current | <120mA |
| Response Time (T90) | <45s |
| Operating Temperature | -10~50℃ |
| Physical Dimensions (L×W×H) | 50×32.4×21mm |
| Product Lifespan (in air) | 3 years |
Source: Instruction Manual for Laser Dust Sensor (Model: ZH03/ZH03A/ZH03B)
All Winsen ZH03B documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the baud rate for UART communication?
The default baud rate for serial communication settings is 9600.
From: Instruction Manual for Laser Dust Sensor (Model: ZH03/ZH03A/ZH03B)
Which PM values are detected by this sensor series?
The sensors detect PM1.0, PM2.5, and PM10 concentrations in the air.
From: Instruction Manual for Laser Dust Sensor (Model: ZH03/ZH03A/ZH03B)
What is the minimum detectable particle diameter?
The minimum detectable particle diameter is 0.3μm.
What are the output interfaces supported?
The sensor supports both UART output and PWM output.