This document is an instruction manual for the laser dust sensor (model: ZH03/ZH03A/ZH03B), including product features, technical specifications, and installation methods.
The document provides usage instructions for the Winsen ZH03/ZH03A/ZH03B series of laser dust sensors. It details product features such as high consistency, real-time response, and low power consumption, along with specific application scenarios including air purifiers and smart home devices.
Technical specifications are listed, covering detection ranges for PM1.0, PM2.5, and PM10, operating voltage of 5V, and dimensions. The guide also explains installation methods to ensure proper airflow and provides detailed communication protocols, including active upload, Q&A mode commands, checksum calculations, and PWM output configurations. This manual is written in Chinese.
| Minimum Resolvable Particle Diameter | 0.3μm |
|---|---|
| Operating Voltage | 5V±0.1V |
| Working Current | <120mA |
| Response Time (T90) | <45s |
| Operating Temperature | -10~50℃ |
| Physical Dimensions (L×W×H) | 50×32.4×21mm |
| Product Lifespan (in air) | 3 years |
The default baud rate for serial communication settings is 9600.
The sensors detect PM1.0, PM2.5, and PM10 concentrations in the air.
The PWM cycle for measuring 0~1000ug/m³ is set to 1000 ms±5%.