Key facts
- Brand
- Winsen
- Model
- MQ-9B
- Category
- sensor
- Industry
- Electronics
- Documents
- 2
- Languages
- ZH · EN
- Last added
- 2026-11-15
Start here

Winsen MQ-9B Carbon Monoxide Gas Sensor User Manual
This manual describes the Winsen MQ-9B semiconductor gas sensor, which uses tin dioxide (SnO2) sensing material and detects carbon monoxide and methane. It explains the high-temperature/low-temperature cycle, with 1.5V heating used to detect CO and 5.0V heating used to clean adsorbed gases.
The document lists product specifications, standard test conditions, the basic test circuit, sensitivity and temperature/humidity characteristic curves, response and recovery behavior, long-term stability, and cautions covering exposure to silicone compounds, corrosive gases, water, condensation, high gas concentrations, vibration, shock, and soldering conditions. This manual is written in Chinese.
Winsen MQ-9B specifications
| Product type | Semiconductor gas sensor |
|---|---|
| Detected gases | Carbon monoxide, methane |
| Detection range | 10–500 ppm CO; 300–10000 ppm CH4 |
| Loop voltage Vc | ≤10V DC |
| Heating voltage VH | 5.0V±0.1V AC or DC (high temperature); 1.5V±0.1V AC or DC (low temperature) |
| Heating time | 60±1 s (high temperature); 90±1 s (low temperature) |
| Heating resistance RH | 29Ω±3Ω (room temperature) |
| Heating power PH | ≤900 mW |
| Sensitivity S | Rs(in air)/Rs(in 150ppm CO)≥5; Rs(in air)/Rs(in 5000ppm CH4)≥3 |
| Output voltage Vs | 2.5–4.3V (in 150ppm CO); 2.0–4.0V (in 5000ppm CH4) |
| Standard test temperature and humidity | 20℃±2℃; 55%±5%RH |
| Preheating time | Not less than 48 hours |
| Oxygen content | 21% (not lower than 18%) |
| Standard package | Plastic sealed |
| Load resistance RL | Adjustable |
All Winsen MQ-9B documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What gases does the MQ-9B detect?
The MQ-9B detects carbon monoxide and methane, with detection ranges of 10–500 ppm CO and 300–10000 ppm CH4.
What heating voltages are required for the MQ-9B?
The heater uses 1.5V±0.1V when detecting carbon monoxide and 5.0V±0.1V during the non-detecting recovery stage.
What gases does the MQ-9B sensor detect?
It detects carbon monoxide (CO) and methane (CH4).
What is the operating voltage for the heater?
The heater operates at 5.0V±0.1V for high temperature and 1.5V±0.1V for low temperature.