Key facts
- Brand
- Winsen
- Model
- MP-5
- Category
- Other Electronics
- Industry
- Industrial
- Documents
- 2
- Languages
- ZH
- Last added
- 2026-10-19
Start here

Winsen MP503 Air Quality Gas Sensor User Manual
The Winsen MP503 is a plane semiconductor gas sensor designed for detecting alcohol, smoke, n-butane, and formaldehyde. It utilizes a multi-layer thick film manufacturing process on an Al2O3 ceramic substrate to provide high sensitivity and fast response times with low power consumption.
This document provides instructions on the basic circuit connections, including heater voltage (VH) and test voltage (VC). It also details technical specifications such as operating temperatures, resistance values, and sensitivity curves. Furthermore, it outlines critical precautions regarding environmental exposure, storage aging requirements based on duration, and specific soldering conditions to ensure sensor longevity. This manual is written in Chinese.
Winsen MP-5 specifications
| Detected Gases | Alcohol, Smoke, n-Butane, Formaldehyde |
|---|---|
| Detection Concentration (Alcohol) | 1~1000ppm |
| Circuit Voltage (VC) | ≤24V DC |
| Heater Voltage (VH) | 5.0V±0.1V AC or DC |
| Heating Resistance (RH) | 95Ω±10Ω at room temperature |
| Heater Power Consumption (PH) | ≤300mW |
| Preheating Time | Not less than 48 hours |
All Winsen MP-5 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What gases does the MP503 sensor detect?
The sensor detects alcohol, smoke, n-butane, and formaldehyde.
How long must the sensor be preheated before use?
The standard preheating time is not less than 48 hours.
What is the recommended preheat time for the MP-5 sensor?
The sensor requires a preheat time of not less than 48 hours.
How does oxygen concentration affect the sensor's performance?
Oxygen concentration affects the sensor's initial value, sensitivity, and repeatability; usage in low oxygen concentrations requires consultation.