Winsen MQ-4B Combustible Gas Sensor User Manual
The Winsen MQ-4B is a semiconductor gas sensor designed for detecting combustible gases, specifically methane. It utilizes a tin dioxide (SnO2) sensing element whose electrical conductivity increases in the presence of combustible gases. The sensor is suitable for use in home gas leak alarms, industrial gas detectors, and portable gas detection devices. This manual is written in Chinese.
Read onlineWinsen MQ-4 specifications
| Detected Gas | Methane |
|---|---|
| Detection Concentration | 300~10000ppm |
| Circuit Voltage | ≤24V DC |
| Heating Voltage | 5.0V±0.1V AC or DC |
| Heating Resistance | 26Ω±3Ω |
All Winsen MQ-4 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the recommended preheating time for the sensor?
The sensor requires a preheating time of no less than 48 hours.
What are the ideal welding conditions for the sensor?
The ideal method is manual soldering using a constant temperature iron at 250°C for no more than 3 seconds.
What gas does the MQ-4 sensor detect?
The MQ-4 sensor is designed to detect methane.
How long should the sensor be pre‑heated before use?
The sensor requires a pre‑heat time of at least 48 hours.
What is the detection range of the MQ-4 sensor?
The detection range is 300 to 10000 ppm for methane (CH4).
What voltage does the heater require?
The heater requires 5.0V±0.1V AC or DC.