Key facts
Start here

Winsen ZH06-Ⅱ Laser Dust Sensor User Manual
The ZH06-Ⅱ is a general-purpose, miniaturized laser dust sensor module from Winsen. It uses Mie scattering to detect airborne dust particles and provides UART and PWM outputs.
The manual lists technical specifications, pin definitions, UART configuration, installation guidance, precautions, packaging, and reliability test information for the sensor. This manual is written in Chinese.
Winsen ZH06-Ⅳ specifications
| Detection particle size range | 0.3-10 μm |
|---|---|
| Effective range | 0-1000 μg/m³ |
| Detection interval | 1 s |
| PM2.5 detection accuracy | 0-100 μg/m³: ±15 μg/m³; 101-1000 μg/m³: ±15% reading |
| Power-on stabilization time | 30 s |
| Operating voltage | 4.9-5.5 V DC |
| Operating current | <120 mA |
| Sleep current | <20 mA |
| Response time | T90 < 45 s |
| Operating humidity | 0-80% RH (no condensation) |
| Operating temperature | -10 to 60 °C |
| Storage temperature | -30 to 70 °C |
| Dimensions | 47 × 37 × 12.2 mm (L × W × H) |
| MTTF | >10000 h continuous uninterrupted |
| UART baud rate | 9600 |
All Winsen ZH06-Ⅳ documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the operating voltage of the ZH06-Ⅱ sensor?
The operating voltage is 4.9 V to 5.5 V DC.
What particle sizes can the ZH06-Ⅱ detect?
The detection particle size range is 0.3-10 μm.
What is the detection particle size range of the ZH06-Ⅳ?
It detects particles in the 0.3–10 μm range.
What output types does the sensor provide?
It can provide UART serial output and PWM output at the same time.
What is the minimum detectable particle diameter?
The sensor can detect particles with a minimum diameter of 0.3μm.
What are the output types of the sensor?
The sensor supports UART TTL output and PWM output, both at 3.3V level.