Key facts
- Brand
- Winsen
- Model
- MQ135
- Category
- Other Electronics
- Industry
- Industrial
- Documents
- 2
- Languages
- ZH
- Last added
- 2026-10-23
Start here

Winsen MQ135 Air Pollution Sensor User Manual
The document describes the Winsen MQ135, a semiconductor gas sensor utilizing tin dioxide (SnO2) to detect various harmful gases such as ammonia, sulfur compounds, and benzene vapors. It is designed for low-cost applications in both home and industrial environments, including gas leak alarms and portable detectors. This manual is written in Chinese.
Read onlineWinsen MQ135 specifications
| Detectable Gases | Ammonia, Sulfur compounds, Benzene vapors |
|---|---|
| Detection Concentration | 10~1000ppm |
| Standard Circuit Voltage | 5.0V±0.1VDC |
| Heating Voltage | 5.0V±0.1VAC or DC |
| Heating Resistance | 30Ω±3Ω |
| Output Voltage | 2.0V~4.0V |
| Preheat Time | Not less than 48 hours |
All Winsen MQ135 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What gases can the MQ135 sensor detect?
The sensor is highly sensitive to ammonia, sulfur compounds, benzene vapors, smoke, and other harmful gases.
What are the standard circuit conditions for the sensor?
The standard test circuit requires a test voltage (Vc) of 5.0V±0.1VDC and a heating voltage (VH) of 5.0V±0.1VAC or DC.
What gases can the MQ135 sensor detect?
The sensor is highly sensitive to ammonia, sulfur compounds, benzene vapors, and smoke.
What is the recommended preheating time for the sensor?
The sensor requires a preheating time of no less than 48 hours.