Winsen MQ136 Hydrogen Sulfide Gas Sensor Datasheet

Winsen MQ136 Hydrogen Sulfide Gas Sensor Datasheet

Datasheet 6 pages · 393 KB · ZH

The MQ136 is a semiconductor gas sensor from Zhengzhou Winsen Electronic Technology. Its sensing material is tin dioxide (SnO2), which has low conductivity in clean air; when hydrogen sulfide is present, conductivity rises with H2S concentration, and a simple circuit can convert this change into an output signal. The document lists a detection range of 1 to 200 ppm and names household H2S alarms, industrial H2S leak alarms, and portable H2S detectors as applications.

The datasheet gives standard circuit conditions, sensitivity and output characteristics, basic test circuits, and typical sensitivity, temperature/humidity, and response/recovery curves. It also lists conditions to avoid, such as silicone vapor, corrosive gases, water, freezing, overvoltage, and wrong pin connections, plus soldering, storage, and aging guidance. This manual is written in Chinese.

Read online

Winsen MQ136 specifications

ModelMQ136
Product typeSemiconductor gas sensor
Standard packageBakelite, metal cover
Detected gasHydrogen sulfide
Detection concentration1 to 200 ppm
Circuit voltage5.0 V ±0.1 V DC
Heater voltage5.0 V ±0.1 V AC or DC
Load resistanceAdjustable
Heater resistance30 Ω ±3 Ω at room temperature
Heater power≤950 mW
SensitivityRs(in air)/Rs(50ppm H2S) ≥3
Output voltage≥0.5 V in 50 ppm H2S
Concentration slope≤0.6 (R200ppm/R50ppm H2S)
Preheat timeNot less than 48 hours
Oxygen content21% (not below 18%)

Source: Winsen MQ136 Hydrogen Sulfide Gas Sensor Datasheet

All Winsen MQ136 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What gas does the MQ136 detect?

The MQ136 is designed to detect hydrogen sulfide.

From: Winsen MQ136 Hydrogen Sulfide Gas Sensor Datasheet

What concentration range does the MQ136 cover?

It covers a detection concentration of 1 to 200 ppm.

From: Winsen MQ136 Hydrogen Sulfide Gas Sensor Datasheet

What is the sensitive material of the MQ136 sensor?

The sensitive material of the MQ136 gas sensor is SnO2.

From: Winsen MQ136 Hydrogen Sulfide Gas Sensor Datasheet