Mitsubishi Electric MELSEC iQ-F FX5 User Manual (Positioning)
This manual provides detailed safety and wiring instructions, startup and maintenance guidelines, and a complete overview of the MELSEC iQ-F FX5 micro‑programmable controller. It also describes the positioning control features, parameters, commands and troubleshooting procedures.
The document includes reference tables for performance specifications, input/output limits, pulse‑output formats, and programming examples using GX Works3. Related manuals and warranty information are listed at the end. This manual is written in Chinese.
Mitsubishi Electric MELSEC iQ-F FX5 specifications
| Control axes (CPU module) | 4 axes |
|---|---|
| Positioning range | -2147483648 ~ +2147483647 (motor/mechanical/combined units) |
| Input signal voltage | DC24 V +20% / –15% |
| Ground wire size (CPU module) | ≥2 mm² |
Source: Mitsubishi Electric MELSEC iQ-F FX5 User Manual (Positioning)
All Mitsubishi Electric MELSEC iQ-F FX5 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Mitsubishi Electric MELSEC iQ-F FX5 SLMP Function User Manual 112 p
- Mitsubishi Electric MELSEC iQ-F FX5 Temperature Control User Manual 172 p
- Mitsubishi Electric MELSEC iQ-R FX5 Series User Manual (Positioning) 192 p
- Mitsubishi Electric MELSEC iQ-R FX5 Series Positioning User Manual 240 p
- Mitsubishi Electric MELSEC iQ-F FX5 User Manual (Positioning) 242 p
Instruction set, parameters and examples for configuring or programming the device.
Questions answered in these manuals
What safety measures are required when connecting external devices to a running device that supports SLMP?
You must read the manual and confirm safety before performing online operations that change the running status, as errors can cause mechanical damage or accidents.
From: Mitsubishi Electric MELSEC iQ-F FX5 SLMP Function User Manual
What specific action is prohibited regarding the buffer memory's system area of intelligent function modules?
You must not write data to the system area of the buffer memory, as doing so creates a risk of system malfunction.
From: Mitsubishi Electric MELSEC iQ-F FX5 SLMP Function User Manual
What is the purpose of this manual?
This manual explains usage content for temperature control modules in the iQ-F series.
From: Mitsubishi Electric MELSEC iQ-F FX5 Temperature Control User Manual
What is the minimum wire cross-section required for grounding?
You must use a wire of 2mm² or larger for Class D grounding.
From: Mitsubishi Electric MELSEC iQ-F FX5 Temperature Control User Manual
What safety measures are required if the CPU module detects an abnormality via its self-diagnosis function?
When the CPU module detects an abnormality, all outputs turn OFF, but external circuits must be designed to ensure the machine runs in a safe state.
From: Mitsubishi Electric MELSEC iQ-R FX5 Series User Manual (Positioning)
What type of contacts must be used for wiring the forward and reverse limit switches?
The wiring for forward and reverse limits must use negative logic with NC contacts to prevent major accidents.
From: Mitsubishi Electric MELSEC iQ-R FX5 Series User Manual (Positioning)