Mitsubishi Electric MR-J5W-G-N1 Manuals

ManualLib has 2 documents for the Mitsubishi Electric MR-J5W-G-N1 (Servo motor): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
MR-J5W-G-N1
Category
Servo motor
Documents
2
Languages
ZH
Last added
2023-11-15

Start here

Mitsubishi Electric MR-J5-G-N1/MR-J5W-G-N1 AC Servo User Manual (Introduction)

Mitsubishi Electric MR-J5-G-N1/MR-J5W-G-N1 AC Servo User Manual (Introduction)

User Manual 124 pages · 9.1 MB · ZH

This is the introduction volume (导入篇) of the user manual for the Mitsubishi Electric MR-J5-G-N1 and MR-J5W-G-N1 AC servo amplifiers, written in Chinese. It begins with safety precautions for installation, wiring, operation and maintenance, and explains how the manual is organized within the MR-J5 manual series, which includes separate volumes for hardware, functions, communication functions, tuning, parameters, object dictionary and troubleshooting.

The manual covers the specifications of the servo amplifiers, model naming, combinations with servo motors, block diagrams, peripheral device configuration, functions including safety, the construction and indicators of the amplifier, startup procedures such as first power-on, test run mode and copying settings with MR Configurator2, as well as servo, network and functional safety parameters and troubleshooting.

Read online

Mitsubishi Electric MR-J5W-G-N1 specifications

FieldbusEtherCAT (CoE), slave
Device profileCiA 402 Drive Profile
Control modescsp, csv, cst, pp, pv, tq, hm
Cyclic synchronous position modeReceives position commands at fixed cycles; absolute position address required
Profile position modePositioning control with absolute or relative position addresses

Source: Mitsubishi Electric MR-J5-G-N1/MR-J5W-G-N1 Servo Amplifier User Manual (Communication and Functions)

All Mitsubishi Electric MR-J5W-G-N1 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

How long should I wait after turning off the power before wiring or inspection?

Wait at least 15 minutes after the power is turned off before performing wiring work or inspection, otherwise electric shock may occur.

From: Mitsubishi Electric MR-J5-G-N1/MR-J5W-G-N1 AC Servo User Manual (Introduction)

How should the servo amplifier be grounded?

The protective earth (PE) terminal of the servo amplifier must be connected to the PE terminal of the control cabinet and earthed to prevent electric shock.

From: Mitsubishi Electric MR-J5-G-N1/MR-J5W-G-N1 AC Servo User Manual (Introduction)

What device type is the MR-J5-G-N1 servo amplifier on an EtherCAT network?

It operates as an EtherCAT slave following the CAN application protocol over EtherCAT (CoE) standard, with device type "drives" supporting the CiA 402 Drive Profile.

From: Mitsubishi Electric MR-J5-G-N1/MR-J5W-G-N1 Servo Amplifier User Manual (Communication and Functions)

Which control modes does the MR-J5-G-N1/MR-J5W-G-N1 support over EtherCAT?

It supports cyclic synchronous position (csp), velocity (csv) and torque (cst) modes, profile position (pp), velocity (pv) and torque (tq) modes, and homing mode (hm).

From: Mitsubishi Electric MR-J5-G-N1/MR-J5W-G-N1 Servo Amplifier User Manual (Communication and Functions)