Key facts
- Brand
- LG
- Model
- iV5
- Category
- Industrial Supply
- Industry
- Industrial
- Documents
- 4
- Languages
- ZH · EN
- Last added
- 2026-11-20
Start here

LG Multi V 5 Variable Refrigerant Flow Outdoor Units 6.0 to 42.0 Tons Operation and Maintenance Manual
This operation and maintenance manual from LG Electronics U.S.A., Inc. covers the Multi V 5 variable refrigerant flow (VRF) outdoor units in capacities from 6.0 to 42.0 tons. It explains safety precautions, unit nomenclature, and general information about the outdoor units and heat recovery units.
The manual also describes day-to-day operation, refrigerant piping insulation, wiring and communication connections, DIP switch settings, equipment addressing, and customized operation settings. Maintenance chapters include a preventive maintenance schedule, the LG VRF System Maintenance & Diagnostic Software, PCB self-diagnostics checks, integrated test run procedures, and troubleshooting with error codes.
LG iV5 specifications
| Control Type | Vector Control / V/F Control |
|---|---|
| Input Voltage | 200V Series / 400V Series |
| Cooling Method | Fan Forced Cooling |
| Communication Interfaces | RS485, DeviceNet, Profibus-DP, Modbus-RTU |
All LG iV5 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
What standards does the LG iV5 series comply with?
The iV5 series complies with CUL and UL standards.
Does the iV5 series support auto-tuning?
Yes, it supports two types of auto-tuning: stop type and rotation type.
What is the refrigerant type used in this unit?
R410A EEV.
From: LG ARUM432DTE5 Multi V 5 36 Ton Triple Frame Heat Pump and Heat Recovery Service Manual
What is the acceptable operating voltage range for this unit?
The unit accepts an operating voltage between 414V and 528V.
From: LG ARUM432DTE5 Multi V 5 36 Ton Triple Frame Heat Pump and Heat Recovery Service Manual
Can I install the LG outdoor unit myself?
No. The manual states that the end user should not install, remove, or re-install the unit; installation must be done by a dealer or an LG trained technician.
What refrigerant does the Multi V 5 outdoor unit use?
The unit uses R410A refrigerant only; using a different refrigerant or mixing air with the original refrigerant will cause malfunction and damage.