Hanna Instruments pH21 Manuals

ManualLib has 3 documents for the Hanna Instruments pH21: 3 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 3

Key facts

Model
pH21
Documents
3
Languages
EN
Last added
2012-07-10

Start here

Hanna Instruments pH 210/211/212/213 Bench Meters Instruction Manual

Hanna Instruments pH 210/211/212/213 Bench Meters Instruction Manual

User Manual 17 pages · 396 KB · EN

This manual provides instructions for the Hanna Instruments pH 210, pH 211, pH 212, and pH 213 microprocessor-based pH and temperature bench meters. The pH 211 and pH 213 models also support ion concentration (ISE) and Oxidation Reduction Potential (ORP) measurements. The instruments feature a large LCD display and support manual or automatic temperature compensation.

Read online

Hanna Instruments pH21 specifications

pH Range-2.00 to 16.00 pH
mV Range+/-399.9 / +/-2000 mV
Temperature Range-9.9 to 120.0°C
pH Resolution0.01 pH
pH Accuracy+/-0.01 pH
Analog Output0 to 5 Vdc not isolated
Dimensions240 x 182 x 74 mm
Weight1.1 kg

Source: Hanna Instruments pH211R Bench pH/mV/C Meter Instruction Manual

All Hanna Instruments pH21 documents by type

Questions answered in these manuals

How often should the instrument be recalibrated for pH?

The instrument should be recalibrated at least once a week, whenever the electrode is replaced, after testing aggressive chemicals, if higher accuracy is required, or after the RESET button is pressed.

From: Hanna Instruments pH211R Bench pH/mV/C Meter Instruction Manual

What buffers are available for calibration?

Five memorized buffers are available: pH 4.01, 6.86, 7.01, 9.18, and 10.01.

From: Hanna Instruments pH211R Bench pH/mV/C Meter Instruction Manual

What buffers are available for calibration?

The instrument offers a choice of five memorized buffers: pH 4.01, 6.86, 7.01, 9.18, and 10.01.

From: Hanna Instruments pH 210/211/212/213 Bench Meters Instruction Manual

How is automatic temperature compensation used?

To use the Automatic Temperature Compensation feature, connect and submerge the HI 7669/2W temperature probe into the sample close to the electrode.

From: Hanna Instruments pH 210/211/212/213 Bench Meters Instruction Manual

What is the pH measurement range?

The meters measure pH in the 0 to 14 range.

From: Hanna Instruments pH20 and pH21 Basic pH Meters Instruction Manual

Can I perform a single point calibration?

Yes, you can choose between 1 or 2 points for automatic calibration.