| Detection particle size range | 0.3-10 μm |
|---|---|
| Effective range | 0-1000 μg/m³ |
| Detection interval | 1 s |
| PM2.5 detection accuracy | 0-100 μg/m³: ±15 μg/m³; 101-1000 μg/m³: ±15% reading |
| Power-on stabilization time | 30 s |
| Operating voltage | 4.9-5.5 V DC |
| Operating current | <120 mA |
| Sleep current | <20 mA |
| Response time | T90 < 45 s |
| Operating humidity | 0-80% RH (no condensation) |
| Operating temperature | -10 to 60 °C |
| Storage temperature | -30 to 70 °C |
| Dimensions | 47 × 37 × 12.2 mm (L × W × H) |
| MTTF | >10000 h continuous uninterrupted |
| UART baud rate | 9600 |
The operating voltage is 4.9 V to 5.5 V DC.
The detection particle size range is 0.3-10 μm.
It is ±15 μg/m³ for 0-100 μg/m³ and ±15% of reading for 101-1000 μg/m³.
The UART baud rate is 9600.