Winsen ZH06-Ⅱ Laser Dust Sensor User Manual

User manual for the Winsen ZH06-Ⅱ laser dust sensor, covering features, specifications, pins, installation, and precautions.


Winsen ZH06-Ⅱ Laser Dust Sensor User Manual - cover page
Brand
Winsen
Category
sensor
Document type
User Manual
Language
Chinese
Pages
12
File format
PDF
File size
1 MB
Published
13 November, 2026
Updated
13 November, 2026
MD5 checksum
250EAC70AA911F53F72353CBAAD6B0E1

About this manual

The ZH06-Ⅱ is a general-purpose, miniaturized laser dust sensor module from Winsen. It uses Mie scattering to detect airborne dust particles and provides UART and PWM outputs.

The manual lists technical specifications, pin definitions, UART configuration, installation guidance, precautions, packaging, and reliability test information for the sensor. This manual is written in Chinese.

What's inside

  • Product description
  • Sensor features
  • Main applications
  • Technical specifications
  • Pin definitions
  • UART configuration
  • Installation
  • Typical output characteristics
  • Precautions
  • Packaging and transport

Specifications

Detection particle size range0.3-10 μm
Effective range0-1000 μg/m³
Detection interval1 s
PM2.5 detection accuracy0-100 μg/m³: ±15 μg/m³; 101-1000 μg/m³: ±15% reading
Power-on stabilization time30 s
Operating voltage4.9-5.5 V DC
Operating current<120 mA
Sleep current<20 mA
Response timeT90 < 45 s
Operating humidity0-80% RH (no condensation)
Operating temperature-10 to 60 °C
Storage temperature-30 to 70 °C
Dimensions47 × 37 × 12.2 mm (L × W × H)
MTTF>10000 h continuous uninterrupted
UART baud rate9600

Frequently asked questions

What is the operating voltage of the ZH06-Ⅱ sensor?

The operating voltage is 4.9 V to 5.5 V DC.

What particle sizes can the ZH06-Ⅱ detect?

The detection particle size range is 0.3-10 μm.

What is the PM2.5 detection accuracy?

It is ±15 μg/m³ for 0-100 μg/m³ and ±15% of reading for 101-1000 μg/m³.

What is the UART baud rate?

The UART baud rate is 9600.