Winsen MC106B Catalytic Combustion Gas Sensor User Manual

This document is the user manual for the catalytic combustion gas sensor (model: MC106B) manufactured by Zhengzhou Winsen Electronic Technology Co., Ltd. The sensor operates based on the principle of catalytic combustion effect and has features such as linear output, fast response, good repeatability, and strong anti-interference performance. It is mainly used for combustible gas leakage alarm or concentration detection. The document also provides information on the technical specifications, sensitivity, and response recovery characteristics of the sensor.


Winsen MC106B Catalytic Combustion Gas Sensor User Manual - cover page
Brand
Winsen
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
7
File format
PDF
File size
461 KB
Updated
28 September, 2023
MD5 checksum
3B882523A3B7EFF5744F0F4245465592

About this manual

This manual describes the Winsen MC106B catalytic combustion gas sensor, which operates based on the catalytic combustion effect. The sensor consists of a detection element and a compensation element paired to form one arm of a bridge circuit. When exposed to combustible gases, the resistance of the detection element increases, causing a proportional change in the bridge output voltage. The compensation element provides reference and temperature/humidity compensation. This manual is written in Chinese.

What's inside

  • Product Description
  • Sensor Features
  • Main Applications
  • Technical Specifications
  • Sensitivity and Response Characteristics
  • Long-term Stability
  • Usage Precautions
  • Welding Instructions

Specifications

Working Voltage2.5±0.1 V
Working Current150±10 mA
Sensitivity (1% Methane)15~45 mV
Sensitivity (1% Propane)25~65 mV
Measurement Range0~100 %LEL
Response Time (90%)≤10s
Recovery Time (90%)≤30s
Operating Temperature-40℃~+70℃
Storage Temperature-20℃~+70℃

Frequently asked questions

What gases is the MC106B sensor suitable for detecting?

It is suitable for detecting combustible gases such as natural gas, liquefied gas, and coal gas in non-industrial public places.

What is the maximum operating voltage for the sensor?

The standard operating voltage is 2.5V with a tolerance of ±0.1V.

How long does it take for the sensor to stabilize after long-term storage?

If stored for a long period (one year), the sensor requires 48 hours of aging to stabilize.

What are the recommended welding conditions for the sensor?

Use rosin flux with the least chlorine, a constant temperature soldering iron, a temperature not exceeding 350℃, and a time not exceeding 5 seconds.