This document introduces the usage instructions and technical specifications of the ZH06-Ⅲ laser dust sensor produced by Zhengzhou Winsen Electronic Technology Co., Ltd. The sensor features good consistency, real-time response, accurate data, and low power consumption. It is suitable for air purifiers, fresh air systems, portable instruments, air quality monitoring devices, air conditioning, smart home devices, and other places.
This manual provides instructions for the Winsen ZH06-III laser dust sensor, a compact module designed to detect airborne dust particles using Mie scattering. It features UART and PWM outputs and is suitable for applications in air purifiers, HVAC systems, and air quality monitoring devices. This manual is written in Chinese.
| Detection Particle Size Range | 0.3-10μm |
|---|---|
| Effective Range | 0-1000μg/m³ |
| Working Voltage | 4.9V~5.5V(DC) |
| Working Current | <120mA |
| Operating Temperature | -10~60℃ |
| Dimensions | 47×37×12.6mm(L×W×H) |
The sensor can detect particles with a minimum diameter of 0.3μm.
The sensor supports UART TTL output and PWM output, both at 3.3V level.
The response time (T90) is less than 45 seconds.