This manual introduces the features and usage methods of MQ-4 gas sensitive sensor, including the structure and working principle of the sensor, application occasions and usage precautions, etc.
This manual provides detailed instructions for using the MQ-4 semiconductor flammable gas sensor, including its technical parameters, circuit connections, and sensitivity characteristics. It also includes important usage precautions to avoid damaging the sensor, such as avoiding exposure to silicon compounds, corrosive gases, or water. The sensor is designed for detecting methane in the range of 300–10000 ppm and is suitable for gas leakage alarms and portable detectors. Proper handling and storage are emphasized to maintain sensor performance over time.
| Target Gas | Methane |
|---|---|
| Detection Range | 300~10000ppm (CH4) |
| Heater Voltage | 5.0V±0.1V AC or DC |
| Load Resistance | Adjustable |
| Output Voltage | 2.5V~4.0V (in 5000ppm CH4) |
| Heater Resistance | 26Ω±3Ω (room temp.) |
| Heater Consumption | ≤950mW |
| Preheat Time | Over 48 hours |
The detection range is 300 to 10000 ppm for methane (CH4).
The heater requires 5.0V±0.1V AC or DC.