Winsen ZP01-MP503 Air Quality Module User Manual

This document is a user manual for the air quality module (model: ZP01-MP503), which describes the features, applications, technical specifications, and precautions of the product.


Winsen ZP01-MP503 Air Quality Module User Manual - cover page
Brand
Winsen
Category
sensor
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
356 KB
Published
01 October, 2022
Updated
27 September, 2023
MD5 checksum
259A1A85CFADE0B79BC15BF0E2FDAA5F

About this manual

The document is a user manual for the Winsen ZP01-MP503 Air Quality Module. It describes the product's features, including high sensitivity to various gases like formaldehyde and benzene, long-term stability, and built-in self-diagnosis capabilities.

The guide details technical specifications such as operating voltage (5V DC), dimensions, and response times. It also explains port definitions for power and signal outputs, provides a table defining the pollution levels based on output signals, and lists important precautions for installation and operation. This manual is written in Chinese.

What's inside

  • Product Description
  • Module Features
  • Main Applications
  • Technical Specifications
  • Port Definitions
  • Output Signal Definition
  • Precautions

Specifications

Operating Voltage5.0±0.2VDC
Working Current≤60mA
Preheat Time≤3 minutes
Response Time≤20 seconds
Recovery Time≤60 seconds
Operating Temperature0~50℃
Dimensions24×20×16mm (L×W×H)

Frequently asked questions

What gases does the ZP01-MP503 module detect?

The module detects formaldehyde, benzene, carbon monoxide, hydrogen, alcohol, cigarette smoke, and fragrance.

What is the maximum operating voltage for this module?

The module should be powered by 5.0±0.2VDC; exceeding 5.5V can cause irreversible damage.

How long does the module need to warm up before use?

The initial power-on usage requires a preheat time of more than 5 minutes.