This document is a user manual for the air quality module (model: ZP01-MP503), which describes the features, applications, technical specifications, and precautions of the product.
The document is a user manual for the Winsen ZP01-MP503 Air Quality Module. It describes the product's features, including high sensitivity to various gases like formaldehyde and benzene, long-term stability, and built-in self-diagnosis capabilities.
The guide details technical specifications such as operating voltage (5V DC), dimensions, and response times. It also explains port definitions for power and signal outputs, provides a table defining the pollution levels based on output signals, and lists important precautions for installation and operation. This manual is written in Chinese.
| Operating Voltage | 5.0±0.2VDC |
|---|---|
| Working Current | ≤60mA |
| Preheat Time | ≤3 minutes |
| Response Time | ≤20 seconds |
| Recovery Time | ≤60 seconds |
| Operating Temperature | 0~50℃ |
| Dimensions | 24×20×16mm (L×W×H) |
The module detects formaldehyde, benzene, carbon monoxide, hydrogen, alcohol, cigarette smoke, and fragrance.
The module should be powered by 5.0±0.2VDC; exceeding 5.5V can cause irreversible damage.
The initial power-on usage requires a preheat time of more than 5 minutes.