This document describes the features and characteristics of the thermal pyroelectric sensor (model: RD-623), including high sensitivity and superior signal-to-noise ratio, dual-element compensation structure, interference resistance due to the metal packaging, and main applications.
The document is a user manual for the Winsen RD-623 pyroelectric infrared sensor. It explains that the device uses a dual-element compensation structure to detect infrared radiation based on temperature changes, making it suitable for security alarms, automatic lighting, and smart home applications.
The guide details technical specifications including sensitivity, detection rate, and operating voltage ranges. It also covers testing methods such as measuring balance degree and frequency characteristics, provides typical application circuit diagrams, and lists reliability test results for conditions like high temperature, humidity, and vibration. This manual is written in Chinese.
| Infrared receiving electrodes | 2×1mm, 2 sensitive elements |
|---|---|
| Window size | 3.8×5mm |
| Receiving wavelength | 5~14µm |
| Output signal peak [Vp-p] | ≥3500mV |
| Sensitivity | ≥3200V/W |
| Detection rate (D*) | 1.4×108cmHz1/2/W |
| Noise peak [Vp-p] | <70mV |
| Output balance degree | <10% |
| Source voltage | 0.3~1.1V |
| Current | <25uA@Rs=47K |
| Power supply voltage (DC) | 3~15V |
| Operating temperature range | -30~70ºC |
The power supply voltage (DC) required for operation is between 3 and 15V.
It is used in safety and intrusion alarms, indoor access management, automatic lighting switches, security doors, smart homes, and intelligent office appliances.
It is calculated by measuring the sensitivity of each unit and using the formula: Balance Degree = |VA-VB|/(VA+VB)×100%.