Winsen MQ-9B user manual covering the semiconductor CO and methane sensor, technical specifications, test circuits, characteristics, and usage cautions.
This manual describes the Winsen MQ-9B semiconductor gas sensor, which uses tin dioxide (SnO2) sensing material and detects carbon monoxide and methane. It explains the high-temperature/low-temperature cycle, with 1.5V heating used to detect CO and 5.0V heating used to clean adsorbed gases.
The document lists product specifications, standard test conditions, the basic test circuit, sensitivity and temperature/humidity characteristic curves, response and recovery behavior, long-term stability, and cautions covering exposure to silicone compounds, corrosive gases, water, condensation, high gas concentrations, vibration, shock, and soldering conditions. This manual is written in Chinese.
| Product type | Semiconductor gas sensor |
|---|---|
| Detected gases | Carbon monoxide, methane |
| Detection range | 10–500 ppm CO; 300–10000 ppm CH4 |
| Loop voltage Vc | ≤10V DC |
| Heating voltage VH | 5.0V±0.1V AC or DC (high temperature); 1.5V±0.1V AC or DC (low temperature) |
| Heating time | 60±1 s (high temperature); 90±1 s (low temperature) |
| Heating resistance RH | 29Ω±3Ω (room temperature) |
| Heating power PH | ≤900 mW |
| Sensitivity S | Rs(in air)/Rs(in 150ppm CO)≥5; Rs(in air)/Rs(in 5000ppm CH4)≥3 |
| Output voltage Vs | 2.5–4.3V (in 150ppm CO); 2.0–4.0V (in 5000ppm CH4) |
| Standard test temperature and humidity | 20℃±2℃; 55%±5%RH |
| Preheating time | Not less than 48 hours |
| Oxygen content | 21% (not lower than 18%) |
| Standard package | Plastic sealed |
| Load resistance RL | Adjustable |
The MQ-9B detects carbon monoxide and methane, with detection ranges of 10–500 ppm CO and 300–10000 ppm CH4.
The heater uses 1.5V±0.1V when detecting carbon monoxide and 5.0V±0.1V during the non-detecting recovery stage.
The standard preheating time is not less than 48 hours.
Hand soldering is preferred with a constant-temperature iron at 250℃ for no more than 3 seconds, using rosin flux with minimal chlorine.