MC119 is a catalytic combustion gas sensor from Zhengzhou Winsen Electronic Technology Co., Ltd. It works by catalytic combustion: a detection element and a compensation element form one arm of a bridge, and the bridge output voltage changes as combustible gas concentration rises. The compensation element provides reference and temperature/humidity compensation.
The manual gives the sensor's technical specifications and performance curves, and lists usage precautions. Its main applications include concentration detection of hydrogen, acetylene, gasoline, and organic vapors such as alcohols, ketones, and benzene at industrial sites. This manual is written in Chinese.
| Product Model | MC119 |
|---|---|
| Product Type | Catalytic combustion gas sensor |
| Standard Package | Metal package, metallurgical powder mesh |
| Operating Voltage | 2.5 ± 0.1 V |
| Operating Current | 100 ± 10 mA |
| Sensitivity (1% H2) | 20–40 mV |
| Sensitivity (1% Acetylene) | 40–90 mV |
| Measuring Range | 0–100 %LEL |
| Response Time (90%) | ≤10 s |
| Recovery Time (90%) | ≤30 s |
| Operating Environment | -40 to +70 °C, below 95% RH |
| Storage Environment | -20 to +70 °C, below 95% RH |
| Dimensions (L × W × H) | 19 × 9.5 × 14 mm |
| Explosion-Proof Marking | ExdibⅠ |
The manual states a measuring range of 0 to 100 %LEL.
The response time (90%) is 10 seconds or less.
In air and in 1% methane, the absolute drift is less than 2 mV per year.