This product data sheet details the Rosemount 2090F hygienic pressure transmitter, which conforms to 3-A standards and supports CIP/SIP service for…
The Rosemount 2090F Hygienic Pressure Transmitter is designed for accurate, stable, and reliable pressure measurement in hygienic industries such as pharmaceuticals and food and beverage. It conforms to 3-A Sanitary Standards and is USDA accepted, with materials of construction recognized as safe (GRAS) by the FDA. The device features CIP/SIP service capabilities for process temperatures up to 284 °F (140 °C) and offers absolute or gauge pressure ranges up to 300 psi with a 20:1 turndown ratio.
| Pressure Ranges | Up to 300 psi (absolute or gauge) |
|---|---|
| Process Temperature | -4 to 284 °F (-20 to 140 °C) |
| Ambient Temperature | -4 to 185 °F (-20 to 85 °C) |
| Output | 4–20 mA dc/digital HART® Protocol |
| Accuracy | ±0.10 percent of calibrated span (P8 option) |
| Process Connection | 1 1/2 or 2-in. Tri Clamp |
| Response Time | 145 ms |
The maximum process temperature is 284 °F (140 °C).
The transmitter provides a 20:1 turndown ratio.