Rosemount 3051G pressure transmitter quick installation manual, mainly introduces the installation, jumper setting, wiring power supply, parameter setting and range adjustment of the transmitter
About this manual
The guide offers basic installation instructions for the Rosemount 3051G pressure transmitter, including safety warnings for explosive environments and references to the full product reference manual for advanced configuration. It emphasizes that the document does not cover detailed troubleshooting, maintenance, or intrinsic safety procedures.
Installation steps are organized into five sections: installing the transmitter, setting jumpers, wiring and powering the device, configuring parameters, and adjusting the measurement range. Additional information on power supply limits, cable requirements, load resistance calculations, and product certifications is also provided. This manual is written in Chinese.
What's inside
- Installation
- Jumper Setting
- Wiring and Power
- Parameter Settings
- Range Adjustment
- Product Certification
- Safety Warnings
Specifications
| Output Signal | 4–20 mA |
|---|
| Cable Requirement | Shielded twisted pair, 24 AWG or larger, max 5,000 ft (1,500 m) |
|---|
| Power Supply Stability | Voltage fluctuation < 2 % |
|---|
| Maximum Loop Resistance | 45.4 × (supply voltage – 10.5) Ω |