Key facts
- Manuals
- 7
- Languages
- ZH · EN
- Last added
- 2026-10-03
Featured Rosemount manuals

Rosemount 644H/644R Smart Temperature Transmitter Quick Installation Guide
This guide provides basic installation instructions for the Rosemount 644H (with LCD) and 644R smart temperature transmitters. It covers safety precautions for explosive environments, electrical shock, and process leaks, as well as required certifications.
The document details configuration procedures, switch settings, wiring, power‑up, and loop testing. It includes tables of shortcut key sequences, typical connection methods for head‑mounted and rail‑mounted units, and a specifications table for ambient temperature limits and HART communication. This manual is written in Chinese.
Covers: Configuration (Bench Calibration) · Validate Configuration · Switch Settings · Transmitter Installation · Wiring and Power‑up · Loop Test

Rosemount 370XA Gas Chromatograph Reference Manual
This reference manual covers all aspects of the Rosemount 370XA gas chromatograph, including a description of the instrument, specifications, certifications, and a detailed equipment overview. It guides users through site requirements, mounting, gas connections, electrical wiring, serial and Ethernet interfaces, and power setup.
The guide also explains normal operation via the local operator interface, preventive maintenance procedures, spare parts, module replacement, overhauling of analytical components, and troubleshooting of common alarms and errors. Appendices provide flowcharts, Modbus® map files, and regulatory information.
Covers: About Rosemount 370XA Gas Chromatographs · Equipment Overview · Installation · Using the Rosemount 370XA · Preventative Maintenance · Recommended Spare Parts

Rosemount 3051SAL/3051L/2051L/1199 Differential Pressure Level Transmitter and Remote Seal Product Manual
This manual describes Rosemount’s differential pressure level transmitters and the 1199 remote‑seal system. The transmitters combine Rosemount pressure‑instrument technology with directly‑installed or remote seals, providing reliable level measurement for harsh processes such as extreme temperatures, corrosive media, and sanitary applications.
The document includes application guidance, technical specifications, ordering information, and detailed diagrams for flange, threaded, sanitary and professional seals. It also explains the ERS™ electronic remote sensor system, performance levels, material options, and warranty terms. This manual is written in Chinese.
Covers: Rosemount 3051S Electronic Remote Sensor (ERS) System · Rosemount 3051S Scalable™ Liquid Level Transmitter · Flange Seals for Rosemount 3051SAL · Rosemount 3051L Liquid Level Transmitter Ordering Information · Rosemount 2051L Liquid Level Transmitter · Direct‑Installation Seal System Ordering Information

Rosemount 3051G Pressure Transmitter Quick Installation Guide
The guide offers basic installation instructions for the Rosemount 3051G pressure transmitter, including safety warnings for explosive environments and references to the full product reference manual for advanced configuration. It emphasizes that the document does not cover detailed troubleshooting, maintenance, or intrinsic safety procedures.
Installation steps are organized into five sections: installing the transmitter, setting jumpers, wiring and powering the device, configuring parameters, and adjusting the measurement range. Additional information on power supply limits, cable requirements, load resistance calculations, and product certifications is also provided. This manual is written in Chinese.
Covers: Installation · Jumper Setting · Wiring and Power · Parameter Settings · Range Adjustment · Product Certification
Latest Rosemount manuals
Rosemount 644H/644R Smart Temperature Transmitter Quick Installation Guide
Quick Start Guide 36 pages · 1.9 MB · ZHQuick installation guide for Rosemount 644H and 644R smart temperature transmitters with safety warnings, wiring, and basic configuration steps.
Rosemount 370XA Gas Chromatograph Reference Manual
User Manual 188 pages · 11.7 MB · ENThe Rosemount 370XA Gas Chromatograph Reference Manual provides installation, operation, maintenance, and troubleshooting instructions.
Rosemount 3051SAL/3051L/2051L/1199 Differential Pressure Level Transmitter and Remote Seal Product Manual
User Manual 264 pages · 10.2 MB · ZHThe Rosemount manual details differential pressure level transmitters (3051SAL, 3051L, 2051L) and 1199 remote seals, covering applications, specifications…
ROSEMOUNT 951 Dry Gas pressure transmitter quick installation Service Manual
Rosemount 3051G Pressure Transmitter Quick Installation Guide
Quick Start Guide 10 pages · 1.2 MB · ZHThis quick installation guide provides step‑by‑step instructions for installing, wiring, configuring and calibrating the Rosemount 3051G pressure transmitter.
ROSEMOUNT 485Annubar Flange Connection Flo-Tap Assembly Item quick installation Service Manual
Rosemount 1151 Series Pressure Transmitter Manual
User Manual 35 pages · 1.1 MB · ZHThe manual provides specifications, configuration, testing, and installation guidance for Rosemount 1151 series pressure transmitters.
Which document do I need?
Quick Start Guide
The shortest path to a working setup, usually only a few pages.
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Rosemount manuals
What safety hazards are warned about in the installation guide?
The guide warns that explosion, electrical shock, and process leaks can cause death or serious injury.
From: Rosemount 644H/644R Smart Temperature Transmitter Quick Installation Guide
What loop resistance is required for the handheld communicator?
The loop resistance must be between 250 Ω and 1,100 Ω.
From: Rosemount 644H/644R Smart Temperature Transmitter Quick Installation Guide
What is the warranty period for the Rosemount 370XA?
The limited warranty covers the instrument for twelve months from the date of initial installation or eighteen months from shipment, whichever expires first.
How many sample streams can the Rosemount 370XA handle?
The instrument can handle up to three sample streams and one calibration stream simultaneously.
How long is the warranty for Rosemount 3051 transmitters?
Rosemount provides a 15‑year limited warranty for the 3051 transmitters and associated seals.
What diaphragm materials can be selected for the seals?
Available diaphragm materials include 316L stainless steel (SST), C‑276 alloy, 400 alloy, and tantalum‑coated options.