Reference manual for the Rosemount 2051 wireless pressure transmitter, covering installation, configuration, operation, maintenance, and troubleshooting.
The Rosemount 2051 Wireless Pressure Transmitter is a pressure, level, and flow measurement device that uses the Wireless HART protocol. This December 2023 reference manual (00809-0100-4102, Rev AB) covers the Rosemount 2051C Coplanar, 2051T In-Line, 2051L Level, and 2051CF Series Flow Meter models.
The manual provides configuration, installation, commissioning, operation and maintenance, and troubleshooting instructions. It also includes safety messages, LCD display setup, calibration procedures, menu trees and Fast Keys, and network design best practices.
| 2051C differential/gauge pressure range | Up to 2000 psi (137.9 bar) |
|---|---|
| 2051C absolute pressure range | Up to 4000 psi (275.8 bar) |
| 2051T pressure range | Gauge/absolute pressure up to 10,000 psi (689.5 bar) |
| 2051L level range | Level and specific gravity up to 300 psi (20.7 bar) |
| 2051CF flow line size | ½-in. (15 mm) to 96 in. (2400 mm) |
| Wireless protocol | Wireless HART |
| Power module | One D size primary lithium-thionyl chloride battery; Green Power Module model 701PGNKF |
| Display | Three-line, seven-digit character LCD |
The manual covers the Rosemount 2051C Coplanar, 2051T In-Line, 2051L Level, and 2051CF Series Flow Meter models.
It uses the Wireless HART protocol.
Yes. The manual states that the power module may be replaced in a hazardous area.
The Smart Wireless Gateway should be installed and functioning properly first.