Rosemount 2051 Wireless Pressure Transmitter Reference Manual

Reference manual for the Rosemount 2051 wireless pressure transmitter, covering installation, configuration, operation, maintenance, and troubleshooting.


Rosemount 2051 Wireless Pressure Transmitter Reference Manual - cover page
Brand
Rosemount
Category
pressure transmitters
Document type
User Manual
Language
English
Pages
104
File format
PDF
File size
3.1 MB
Published
18 November, 2026
Updated
18 November, 2026
Model
2051
MD5 checksum
93F8FED9A00A31745100440C2A01C4CC

About this manual

The Rosemount 2051 Wireless Pressure Transmitter is a pressure, level, and flow measurement device that uses the Wireless HART protocol. This December 2023 reference manual (00809-0100-4102, Rev AB) covers the Rosemount 2051C Coplanar, 2051T In-Line, 2051L Level, and 2051CF Series Flow Meter models.

The manual provides configuration, installation, commissioning, operation and maintenance, and troubleshooting instructions. It also includes safety messages, LCD display setup, calibration procedures, menu trees and Fast Keys, and network design best practices.

What's inside

  • Introduction
  • Configuration
  • Installation
  • Commissioning
  • Operation and maintenance
  • Troubleshooting
  • Reference data
  • Communication device Menu Trees and Fast Keys
  • Network design best practices

Specifications

2051C differential/gauge pressure rangeUp to 2000 psi (137.9 bar)
2051C absolute pressure rangeUp to 4000 psi (275.8 bar)
2051T pressure rangeGauge/absolute pressure up to 10,000 psi (689.5 bar)
2051L level rangeLevel and specific gravity up to 300 psi (20.7 bar)
2051CF flow line size½-in. (15 mm) to 96 in. (2400 mm)
Wireless protocolWireless HART
Power moduleOne D size primary lithium-thionyl chloride battery; Green Power Module model 701PGNKF
DisplayThree-line, seven-digit character LCD

Frequently asked questions

What models are covered by the Rosemount 2051 Wireless reference manual?

The manual covers the Rosemount 2051C Coplanar, 2051T In-Line, 2051L Level, and 2051CF Series Flow Meter models.

What wireless protocol does the Rosemount 2051 use?

It uses the Wireless HART protocol.

Can the power module be replaced in a hazardous area?

Yes. The manual states that the power module may be replaced in a hazardous area.

What should be installed before wireless devices are installed?

The Smart Wireless Gateway should be installed and functioning properly first.