This guide summarizes the basic steps for installing, starting up, and programming the Rockwell Automation PowerFlex 40 Adjustable Frequency AC Drive (FRN…
This document serves as a Quick Start guide for the Rockwell Automation PowerFlex 40 Adjustable Frequency AC Drive, specifically models with frame numbers FRN 5.xx through 6.xx. It is intended strictly for qualified drive service personnel and summarizes the essential procedures required to install, start-up, and program the unit.
The guide provides critical safety precautions regarding high voltage capacitors and electrostatic discharge (ESD), along with specific mounting considerations such as orientation, clearance requirements, and ambient temperature limits. It also details electrical ratings for various input/output configurations and includes instructions for removing MOV jumpers on ungrounded distribution systems.
| Output Frequency Range | 0-400 Hz (Programmable) |
|---|---|
| Typical Efficiency | 97.5% |
| Digital Control Input Current | 6mA |
| SRC Mode Voltage ON/OFF | 18-24V = ON, 0-6V = OFF |
| SNK Mode Voltage ON/OFF | 0-6V = ON, 18-24V = OFF |
| Analog Input Impedance (4-20mA) | 250 ohm |
This information is intended for qualified drive service personnel only.
One must wait three minutes for capacitors to discharge to safe voltage levels.