Datasheet for LAPP servo motor, resolver and encoder cables (P/N 7072500-7072517) for Lenze power drive systems.
This data sheet covers LAPP servo motor and signal cables for Lenze power drive systems. The cables are servo-motor, resolver and encoder cables for interconnection between frequency converters and servo drives in industrial machines.
Part numbers 7072500-7072508 are for static use only, while 7072509-7072517 are highly flexible versions suitable for continuous flexing and static use. The sheet lists conductor, insulation, screening, sheath, voltage, temperature, bending radius and other technical data.
| Conductor (P/N 7072500-7072508) | Bare copper, fine wire stranding per IEC 60228 Class 5 |
|---|---|
| Conductor (P/N 7072509-7072517) | Bare copper, extra fine wire stranding per IEC 60028 Class 6 |
| Insulation (power leads 1.0-2.5 mm2) | Polyolefine |
| Insulation (power leads 4-16 mm2) | TPE-E |
| Insulation (control pair) | TPE-E |
| Insulation (resolver and encoder cables) | Polyethylene |
| Core identification (power leads) | Black cores with white printing (U, VV, WWW, green/yellow) |
| Screen (motor and servo motor cables) | Tinned copper braid, 80% nominal optical coverage |
| Outer sheath (P/N 7072500-7072508) | PVC, oil resistant, flame retardant |
| Outer sheath (P/N 7072509-7072517) | PUR, oil resistant, halogen free, flame retardant |
| Rated voltage (power leads) | 600/1000 V (IEC), 600 V (UL) |
| Rated voltage (control pair) | 250 V AC (IEC), 600 V (UL/CSA) |
| Rated voltage (encoder/resolver cables) | 300 V (UL/CSA), 30 V (IEC) |
| Test voltage (motor and servo cables) | 4000 V (control pair 2000 V) |
| Test voltage (encoder/resolver cables) | C/C 1500 V, C/S 800 V |
| Temperature range (P/N 7072509-7072517, flexible) | -5 C to +70 C, signals up to +80 C max. core temp |
| Temperature range (P/N 7072509-7072517, static) | -30 C to +70 C, signals up to +80 C max. core temp |
| Temperature range (P/N 7072500-7072508, static) | -25 C to +80 C max. core temp |
| Minimum bending radius (P/N 7072509-7072515, flexing) | 10 x cable outer diameter |
| Minimum bending radius (P/N 7072516-7072517, flexing) | 15 x cable outer diameter |
| Minimum bending radius (P/N 7072500-7072507, static) | 7.5 x cable outer diameter |
| Oil resistance | Per IEC 60811-2-1 |
| Approvals (motor and servo cables) | UL AWM, CSA AWM I/II A/B |
| EEC conformity | Conforms to European Low Voltage Directive 73/23 |
| Outer diameter (P/N 7072507 resolver cable) | ca. 9.3 mm |
| Outer diameter (P/N 7072508 encoder cable) | ca. 11.0 mm |
| Outer diameter (P/N 7072516 resolver cable) | ca. 10.0 mm |
| Outer diameter (P/N 7072517 encoder cable) | ca. 11.5 mm |
| Pair screening coverage | Greater than 75% |
P/Ns 7072500-7072508 are for static use only.
No, usage inside moving cable carriers is not allowed.
They have UL AWM and CSA AWM I/II A/B approvals.
300 V (UL/CSA) and 30 V (IEC).