Operating guide for Dytran's Series 7563AX triaxial accelerometer with CVLD interface, covering operation, cable length, and maintenance.
This guide explains how to operate the Dytran Series 7563AX triaxial accelerometer with CVLD interface, including its current output behavior and power requirements. It details cable length limitations and how to avoid oscillation. The guide also covers maintenance and repair procedures, including how to obtain RMA authorization for returns.
The accelerometer uses a capacitive sensing element and is designed for zero-to-medium frequency applications. It features a hermetically sealed stainless steel case and is compatible with 4-20mA signal loops, offering low noise and EMI immunity.
| Output Current Bias | 14-15 mA |
|---|---|
| Full Scale Output | ±5mA from bias current |
| Supply Voltage | 10 to 36 volts |
| Cable Length Limit | 15 meters (50 feet) |
The bias current is nominally 14-15 mA at zero acceleration.
For lengths longer than 15 meters, check for oscillation by tapping the accelerometer and watching the current output in the 20kHz to 50kHz region. If no oscillation is present, the cable length is acceptable.
The CVLD interface offers lower noise, high immunity to EMI/EMC interference, simplified wiring (only two wires), and long cable runs.