The Amprobe AM-510 multimeter user manual provides safety information, features, measurement instructions, specifications, and maintenance guidance.
This manual covers safety requirements, unpacking, inspection, and warranty details for the Amprobe AM-510 commercial/residential multimeter. It explains the device’s built‑in flashlight, kick‑stand, probe holder, and CAT III 600 V safety rating.
The guide describes how to perform voltage, current, resistance, continuity, diode, capacitance, frequency, and non‑contact voltage measurements, as well as battery testing. It also lists technical specifications, maintenance procedures, and instructions for battery and fuse replacement.
| Maximum Voltage | 600 V AC/DC |
|---|---|
| Maximum Current | 10 A AC/DC |
| Battery Type | 9 V (6F22) or equivalent |
| Fuse F1 | 0.5 A fast, 660 V, 6.3×32 mm |
| Fuse for 10 A input | 10 A fast, 660 V, 6.3×32 mm |
| Safety Category | CAT III 600 V |
The product is covered for one year from the date of purchase, unless local laws require otherwise.
It uses a 9 V (6F22) battery or an equivalent.