Amprobe SM-10 Sound Meter Data Sheet

The Amprobe SM-10 sound level meter conforms to the IEC651 Type 2, ANSI S1.4 Type 2, and JISC1502 requirements for Sound Level Meters. A and C weightings for checking compliance with safety regulations as well as acoustic analysis


Amprobe SM-10 Sound Meter Data Sheet - cover page
Brand
Amprobe
Category
Other
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
181 KB
Published
02 May, 2012
Updated
01 October, 2023
MD5 checksum
A6C63CAC992B9A401E57FCF10C378913

About this manual

The Amprobe SM-10 Sound Meter is a handheld instrument designed for safety engineers, health and industrial safety offices, and quality‑control personnel. It provides A‑weighting and C‑weighting measurements to meet IEC‑651 Type 2, ANSI 1.4 Type 2 and JISC1502 requirements.

The device features a 4‑digit LCD with 0.1 dB steps, selectable fast (125 ms) and slow (1 s) response times, and accessories such as a carrying case, windscreen and 9 V battery. It operates on a 9 V NEDA 1604 battery with an approximate 50‑hour life and includes auto power‑off after about 5 minutes of inactivity.

What's inside

  • Data Sheet
  • General Specifications
  • Display
  • Power Supply
  • Frequency Range
  • Measuring Level Range
  • Accuracy
  • Calibration Cycle
  • Dimensions
  • Compliance

Specifications

A‑weighting range30 – 130 dB
C‑weighting range35 – 130 dB
Frequency range31.5 Hz – 8 kHz
Display4‑digit LCD, 0.1 dB steps
Power supply9 V NEDA 1604 battery
Battery life≈ 50 hours (alkaline)
Auto power‑off≈ 5 min
Dimensions200 × 55 × 38 mm
Weight233 g (0.5 lb)
Accuracy± 1.5 dB
Calibration cycle1 year

Frequently asked questions

What is the measuring range of the SM‑10?

The SM‑10 measures 30 – 130 dB with A‑weighting and 35 – 130 dB with C‑weighting.

How long does the battery last on the SM‑10?

The battery provides approximately 50 hours of operation with an alkaline 9 V battery.

What frequency range can the SM‑10 measure?

It covers frequencies from 31.5 Hz up to 8 kHz.

What is the accuracy of the SM‑10 sound level readings?

The instrument’s accuracy is ± 1.5 dB.

Download PDF (181 KB)