Datasensor THR Series 1/16 DIN Microprocessor Temperature Controller Instruction Manual

The THR series is a 1/16 DIN microprocessor temperature controller with the following features: - Automatic tuning - Flashing LED indication - 1st point output ON LED - Process value display - 2nd point output ON LED


Datasensor THR Series 1/16 DIN Microprocessor Temperature Controller Instruction Manual - cover page
Brand
Datasensor
Category
Temperature monitor
Document type
User Manual
Language
English
Pages
1
File format
PDF
File size
144 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
013F8A34F556B9AB403F6150940A1C4B

About this manual

The THR Series is a 1/16 DIN microprocessor temperature controller from DATASENSOR S.p.A. This instruction manual presents the control panel, technical data, standard configuration, relay and transistor output connections, dimensions and panel installation, and procedures for viewing and setting the two set points.

Configuration levels, programming notes, error messages and the LFA regulation-loop fault detection are also described. The document includes a declaration of conformity, a 36-month warranty statement, and the contact address for DATASENSOR S.p.A.

What's inside

  • Control panel
  • Technical data
  • Standard configuration
  • Connections
  • Dimensions and installation
  • Viewing and setting of the 1st set point
  • Viewing and setting of the 2nd set point
  • Programming notes
  • Error and messagges
  • LFA: detection of faults in the regulation loop

Specifications

Power supply (THR-0x)10 … 30 Vdc
Power supply (THR-1x)230 Vac ± 10%, 50/60 Hz
Power consumption5 VA max.
Thermocouple inputTypes J, K, E, T, R, S, L
RTD inputPt100 Ω/0 °C per DIN43760, two-wire
Measurement precisionRTD ±0.4% fs; TC ±0.5% fs, ±1 digit
1st point output (relay)SPST 250 Vac, 5 A on resistive load
1st point output (transistor)PNP, 20 mA, protected against short circuit
2nd point outputRelay SPST 250 Vac, 5 A on resistive load
Refresh time500 ms for input, output and indications
Operating temperature-10 … +55 °C
Storage temperature-20 … +65 °C
Humidity35 … 85% rH non-condensing
Mechanical protectionIP54 front panel; IP20 case and contacts
Dimensions48 x 48 x 95 mm
Weight125 g max.

Frequently asked questions

What power supply does the THR-1x version use?

The THR-1x version uses 230 Vac ±10%, 50/60 Hz.

Which sensor types does the THR Series accept?

It accepts thermocouples type J, K, E, T, R, S and L, plus RTD Pt100 Ω/0 °C with two-wire connection.

What is the panel cut-out size for the THR Series?

The panel cut-out is 45.5 x 45.5 mm.

How do you enter the second and third configuration levels?

Keep the PROG key depressed for more than 2 seconds.

Download PDF (144 KB)

More Datasensor Manuals