This document describes the features and specifications of the Baumer Hübner GmbH Absolute encoder EtherNet/IP (with bus cover) product.
This manual describes Baumer absolute encoders with an EtherNet/IP bus cover, firmware version 1.07 and up. It lists the scope of delivery and product allocation for HMG10 / PMG10 multiturn and singleturn versions.
The document explains the CIP device profile and object model, then covers electrical connection, operating and activity displays, IP address allocation, device configuration, and an RSLogix5000 project example for reading input data and setting a preset.
| Firmware version | 1.07 and up |
|---|---|
| Device profile | Encoder Device Profile, device type 22 hex |
| Maximum countable revolutions | Max. 16 bit |
| Physical singleturn resolution | Max. 13 bit |
| I/O data transport | UDP |
| I/O data port | 2222 |
It is used to record positions and speeds and provides measuring values as electronic output signals.
Baumer encoders with the EtherNet/IP bus cover support the Encoder Device Profile, device type 22 hex.
I/O data is transmitted by UDP and uses port 2222.
No, the encoder is maintenance-free and must not be opened up.