Baumer VeriSens Provider Software User's Guide

This manual describes how to use the Baumer VeriSens provider.


Baumer VeriSens Provider Software User's Guide - cover page
Brand
Baumer
Category
Other software
Document type
Programming Manual
Language
English
Pages
17
File format
PDF
File size
570 KB
Published
09 November, 2023
Updated
09 November, 2023
MD5 checksum
3ABBB937D1B5E2063C495AFB2B56EFC4

About this manual

This user's guide describes the Baumer VeriSens Provider, version 1.0.2, which is used for communication with a VeriSens Smart Camera from BAUMER. The provider connects over the TCP/IP Ethernet communication interface and can be used from a PC with high-level languages or directly from the RC8 controller using the DENSO PacScript language; the provider acts as a client and the camera as a server waiting for commands. The revision history lists version 1.0.0 (2012-8-02, first edition) and version 1.0.2 (2013-6-24, TimeOut option included), and the hardware table names the VeriSens ID, CS, XF and XC series.

The guide explains the CaoWorkspace::AddController and CaoController::Execute methods, including the Conn and TimeOut option strings, and then gives a command reference for IsConnected, IsSetupMode, IsRunMode, RebootDevice, GetCurrentJob, ClearStatistics, GetData, GetDataXYR, GetImage, DoTrigger, DoTriggerAndGetData, SwitchToSetupMode and SwitchToRunMode. It closes with a sample program and the camera-side preparation for GetDataXYR: device settings with TCP protocol on port 23 and an end identifier of , adding the "Point position" feature to the current job, and building an output string that starts with "S" and ends with "E" with semicolons between coordinates.

What's inside

  • Introduction
  • Outline of provider
  • CaoWorkspace::AddController method
  • CaoController::Execute method
  • Command reference
  • Sample program
  • Preparing the Baumer VeriSens Camera for the GetDataXYR function
  • Device settings
  • Point position setup
  • Output process interface setup

Specifications

Provider file nameBaumerVeriSens.dll
ProgIDCaoProv.BAUMER.VeriSens
Provider name (fixed)BAUMER.VeriSens
Communication interfaceTCP/IP Ethernet
Port number23 (fixed)
Default TimeOutInfinite
Supported hardwareVeriSens ID Series, VeriSens CS Series, VeriSens XF Series, VeriSens XC Series
Document version1.0.2

Frequently asked questions

What is the VeriSens Provider used for?

It is used for communication with a VeriSens Smart Camera from BAUMER, with the connection based on the TCP/IP Ethernet communication interface.

What does the GetDataXYR command return if no item is detected?

The return value would be (0,0,0).

Which port number does the Ethernet connection use?

Port number 23, which is fixed.

How must the output string for GetDataXYR be formatted?

It has to start with an "S" and end with an "E", with a semicolon as separator between two coordinates.

Download PDF (570 KB)