Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System Profile 1 User Guide

BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System - Profile 1 User Guide


Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System Profile 1 User Guide - cover page
Brand
Balluff
Category
sensor
Document type
User Manual
Language
English
Pages
164
File format
PDF
File size
11.3 MB
Published
08 November, 2023
Updated
08 November, 2023
Model
S115
MD5 checksum
E7F2C045E84B541892B9DA5CFFD44520

About this manual

The Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ is a magnetostrictive position measuring system in profile style 1 with a digital P interface. It measures position along a waveguide using a position magnet and outputs digital time information between start and stop pulses.

The guide covers installation and electrical connection, commissioning, P-interface protocol parameters, technical data, accessories, type code, and appendix information. Up to 16 position magnets can be used, with a minimum spacing of 65 mm between them.

What's inside

  • Validity and scope
  • Symbols and conventions
  • Safety and intended use
  • Design and function
  • Installation and connection
  • Commissioning
  • P interface and protocol parameters
  • Technical data
  • Accessories
  • Type code and appendix

Specifications

Resolution, position1 µm
Non-linearity at nominal length ≤ 500 mm±50 µm
Hysteresis≤ ±10 µm
Repeat accuracy≤ ±5 µm
Ultrasonic velocity (standardized)2850 m/s
Gradient (standardized)8.9122807 µs/inch
Max. detectable velocity10 m/s
Ambient temperature−40…+85°C
Storage temperature−40…+100°C
Humidity< 90%, non-condensing
Degree of protection, connector S32/S115 (when attached)IP67
Current draw at 24 V DC≤ 100 mA
Max. number of magnets16

Frequently asked questions

How many position magnets can be used with the BTL7-P511?

Up to 16 position magnets can be used.

What is the minimum distance between position magnets?

The minimum distance between position magnets must be 65 mm.

What does a green LED 1 indicate?

A green LED 1 indicates normal function with the position magnet within the limits.

What does a red LED 1 indicate?

A red LED 1 indicates an error: no position magnet or a position magnet outside the limits.