BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System - Profile 1 User Guide
The Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ is a magnetostrictive position measuring system in profile style 1 with a digital P interface. It measures position along a waveguide using a position magnet and outputs digital time information between start and stop pulses.
The guide covers installation and electrical connection, commissioning, P-interface protocol parameters, technical data, accessories, type code, and appendix information. Up to 16 position magnets can be used, with a minimum spacing of 65 mm between them.
| Resolution, position | 1 µm |
|---|---|
| Non-linearity at nominal length ≤ 500 mm | ±50 µm |
| Hysteresis | ≤ ±10 µm |
| Repeat accuracy | ≤ ±5 µm |
| Ultrasonic velocity (standardized) | 2850 m/s |
| Gradient (standardized) | 8.9122807 µs/inch |
| Max. detectable velocity | 10 m/s |
| Ambient temperature | −40…+85°C |
| Storage temperature | −40…+100°C |
| Humidity | < 90%, non-condensing |
| Degree of protection, connector S32/S115 (when attached) | IP67 |
| Current draw at 24 V DC | ≤ 100 mA |
| Max. number of magnets | 16 |
Up to 16 position magnets can be used.
The minimum distance between position magnets must be 65 mm.
A green LED 1 indicates normal function with the position magnet within the limits.
A red LED 1 indicates an error: no position magnet or a position magnet outside the limits.