Key facts
- Brand
- Balluff
- Model
- S115
- Category
- Industrial Robot
- Documents
- 3
- Languages
- EN
- Last added
- 2023-11-08
Start here

Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System Profile 1 User Guide
The Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ is a magnetostrictive position measuring system in profile style 1 with a digital P interface. It measures position along a waveguide using a position magnet and outputs digital time information between start and stop pulses.
The guide covers installation and electrical connection, commissioning, P-interface protocol parameters, technical data, accessories, type code, and appendix information. Up to 16 position magnets can be used, with a minimum spacing of 65 mm between them.
Balluff S115 specifications
| Resolution, position | 1 µm |
|---|---|
| Non-linearity at nominal length ≤ 500 mm | ±50 µm |
| Hysteresis | ≤ ±10 µm |
| Repeat accuracy | ≤ ±5 µm |
| Ultrasonic velocity (standardized) | 2850 m/s |
| Gradient (standardized) | 8.9122807 µs/inch |
| Max. detectable velocity | 10 m/s |
| Ambient temperature | −40…+85°C |
| Storage temperature | −40…+100°C |
| Humidity | < 90%, non-condensing |
| Degree of protection, connector S32/S115 (when attached) | IP67 |
| Current draw at 24 V DC | ≤ 100 mA |
| Max. number of magnets | 16 |
All Balluff S115 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System Profile 1 User Guide 164 p
- Balluff BTL7-A/C/E/G1 _ _-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S135/KA_ _ Micropulse Linear Transducer - User's Guide 27 p
- Balluff BIS L-400-035-00_-00-S115 Identification System User Manual 16 p
Questions answered in these manuals
How many position magnets can be used with the BTL7-P511?
Up to 16 position magnets can be used.
What is the minimum distance between position magnets?
The minimum distance between position magnets must be 65 mm.
What is the intended use of the BTL7 transducer?
It is part of a displacement measurement system with a machine controller (PLC) for measuring position in machinery.
What is the intended use of the BTL7 Micropulse Transducer?
It comprises a displacement measurement system fitted into a machine or piece of equipment for its application.
What is the purpose of the CRC_16 data check?
It adds a 2-byte CRC_16 checksum to data for high integrity, but reduces user data capacity to 3 bytes.
From: Balluff BIS L-400-035-00_-00-S115 Identification System User Manual
How does the processor output data to a host system?
Data are output in 8-bit blocks over 8 parallel data lines and made available to host systems like industrial PCs or PLCs.
From: Balluff BIS L-400-035-00_-00-S115 Identification System User Manual