Agilent ESA Series Spectrum Analyzer Product Leaflet

The ESA series spectrum analyzers offer flexible performance, price and platform. Three Express analyzers are available: the ESA basic configuration analyzer, the ESA standard analyzer and the ESA communications test analyzer.


Agilent ESA Series Spectrum Analyzer Product Leaflet - cover page
Brand
Agilent
Category
Other Electronics
Document type
Product Leaflet
Language
Chinese
Pages
24
File format
PDF
File size
4.4 MB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
7C61EA1A11C6225AE5246E64B07B9299

About this manual

The Agilent ESA series spectrum analyzer offers three Express configurations designed to provide rapid delivery and optimal value for RF and microwave signal analysis. These models include the Basic, Standard, and Communication Test Analyzer configurations, each tailored to specific needs ranging from basic spectrum analysis to advanced vector signal analysis with demodulation capabilities.

Key features include high accuracy with guaranteed total amplitude accuracy of less than 1.0 dB, a frequency range extending up to 26.5 GHz, and a dynamic range established by a third-order intermodulation distortion performance of +16 dBm. The instrument supports various detection modes, including RMS, peak, and quasi-peak, and includes built-in power measurement functions and standard test settings for wireless standards such as GSM EDGE, CDMA2000, and Bluetooth. This manual is written in Chinese.

What's inside

  • Express Analyzer Configurations
  • Leading Performance
  • Amplitude Accuracy
  • Dynamic Range
  • Preheat Time
  • Built-in Power Measurement
  • Standard Test Settings
  • Hardware and Software Flexibility

Specifications

Frequency RangeE4407: 9 kHz - 26.5 GHz
Amplitude AccuracyLess than 1.0 dB (< 3 GHz)
Phase Noise-101 dBc/Hz at 10 kHz offset
Minimum Sweep Time1 ms in frequency domain
Third-Order Intercept (TOI)+16 dBm
Display Average Noise Level (DANL)Better than -167 dBm

Frequently asked questions

What is the preheat time required for the ESA series?

The ESA series requires only 5 minutes of preheat time to reach guaranteed performance.

What is the minimum warm-up time required for the Agilent ESA spectrum analyzer to reach guaranteed performance?

The instrument reaches guaranteed performance after only 5 minutes of warm-up time.

What is the shortest radio frequency scan time available for the Agilent ESA series?

The shortest radio frequency scan time is 1 ms.

What is the minimum resolution bandwidth achievable with the optional high stability time base?

The minimum resolution bandwidth is 1 Hz when the high stability time base option is ordered.