RIGOL's RP5600A passive oscilloscope probe has a bandwidth of up to 600 MHz and a modular design that allows the probe tip assembly to be replaced. The probe is compact in design and its snap-on BNC connector allows for easy connection to the oscilloscope.
The RIGOL RP5600A is a passive oscilloscope probe with a 600 MHz analog bandwidth, a fixed 10:1 attenuation ratio, and a compact snap-on BNC connector. The manual describes general inspection, standard accessories, connecting the probe to an oscilloscope, probe use, and compensation adjustment.
Performance specifications list 10 MΩ input impedance, 12 pF input capacitance, CAT II 300 VAC maximum input, and a 6 pF to 26 pF compensation range. The document also includes maintenance and cleaning, warranty, and contact information. This manual is written in Chinese.
| Bandwidth | DC~600 MHz |
|---|---|
| Attenuation Ratio | Fixed 10:1 |
| Input Impedance | 10 MΩ ±2% |
| Input Capacitance | 12 pF ±1 pF |
| Maximum Input | CAT II 300 VAC |
| Compensation Range | 6 pF~26 pF |
| Operating Environment | Temperature 0 °C~50 °C, humidity 0 RH~80% RH |
| Storage Environment | Temperature -20 °C~60 °C, humidity 0 RH~90% RH |
| Probe Dimensions | 142±2 cm |
| Probe Weight | Approximately 48±2 g |
The specified bandwidth is DC to 600 MHz.
The RP5600A has a fixed 10:1 attenuation ratio.
The maximum input is CAT II 300 VAC.
The compensation range is 6 pF to 26 pF.