This document provides detailed information about the Micro Motion 775 Type Intelligent Wireless Integral THUM Adapter, including installation considerations, locating the THUM adapter, THUM adapter wiring requirements, wiring the integral THUM adapter, and post-installation and THUM adapter configuration
This wiring supplement from Micro Motion (高准) covers the Model 775 intelligent wireless integral THUM adapter. It describes what the adapter does, where to position it, what wiring it needs, and how to connect it to a Micro Motion transmitter. The document states that it is not a complete guide to the wireless THUM adapter; for installation and configuration it refers readers to the Smart Wireless THUM Adapter Quick Installation Guide and Reference Manual, available on the Micro Motion product documentation CD or at www.micromotion.com.
The supplement explains that the THUM adapter extends the HART functionality of a transmitter's primary mA output and passes HART data onto a wireless HART network, and that it is mounted integrally on the transmitter using certified thread sealant at a torque of 30–35 ft-lbs. Wiring tables show which adapter wires go to the transmitter terminals for internally powered (active) and externally powered (passive) mA outputs, including the green ground wire and the extra ground screw inside the 2200S housing. Installation considerations cover mounting position, separation from metal surfaces, antenna spacing and hazardous-area precautions. Illustrations show the adapter installed in a 2700 transmitter and a 2200S transmitter, and the transmitter wiring compartment connections. This manual is written in Chinese.
| Mounting torque | 30–35 ft-lbs |
|---|---|
| Minimum antenna separation from personnel | 7.9" (20 cm) |
| Voltage drop on signal loop | 2.25 V at 3.5 mA to 1.2 V at 25 mA, linear |
| Maximum voltage drop in fault condition | 2.5 V |
| Required voltage margin at 250 ohm load | at least 2.5 V |
| Conduit seal location | within 18" (45.7 cm) of the transmitter conduit opening |
| Recommended mounting position | Vertical, straight up or straight down |
It extends the HART capability of the transmitter's primary mA output and passes the HART data from the transmitter onto a wireless HART network.
The red wire goes to the mA + terminal and the black wire to the mA – terminal, while the yellow and white wires are spliced to the mA output wiring.
Wait 5 minutes before opening the transmitter wiring compartment if the transmitter is installed in a hazardous area.