The User Manual provide information about using, configuration and connecting the TriBoard with Infineon AURIX™ TC3X7 device.
This document provides detailed information on using, configuring, and connecting the TriBoard TC3X7 TH V1.0 and TriBoard TC3X7 V1.0 hardware boards with Infineon’s TC3X7 (e.g. TC397) AURIX™ microcontrollers. It covers power supply, LEDs, clock, USB, FlexRay™, CAN, LIN, Ethernet, and debug systems. The boards include various peripherals and connectors for development and testing. Intended for design, verification, test, and software engineers working with TriCore applications.
The boards differ slightly in component placement, especially around the TC3X7, due to through-hole sockets versus soldered components, but most components are in the same locations. The manual includes schematics, pin assignments, and known issues for both board versions.
| Microcontroller | Infineon’s TC3X7 (TC397) AURIX™ 2G Controller in LFBGA-292 Package |
|---|---|
| FlexRay™ Transceivers | 2 x Infineon’s FlexRay™ Transceiver TLE9221SX |
| CAN Transceivers | 2 x Infineon’s High Speed CAN-Transceiver TLE9251VSJ |
| LIN Transceiver | Infineon’s LIN-Transceiver TLE 7259-3GE |
| Ethernet PHY | Single Port Gigabit Ethernet PHY PEF7071 (LANTIQ) |
| Power Supply | Infineon’s Multi Voltage Safety Micro Processor Supply TLF35584QV |
The boards differ slightly in component placement around the TC3X7 due to through-hole sockets versus soldered components, but most components are in the same locations.
It is used for developing and testing TriCore applications with Infineon AURIX™ TC3X7 devices.
There are two types: TriBoard TC3X7 TH with Through Hole socket and TriBoard TC3X7 with soldered devices.
The board requires a +3.5V to +40V DC power supply.