Extech 422123 Precision Multifunction Calibrator User Manual

This document describes the features and functions of the Extech 422123 Precision Multifunction Calibrator, including output mA, mV, V, Temperature (°C/°F) and Frequency, and the method of use.


Extech 422123 Precision Multifunction Calibrator User Manual - cover page
Brand
EXTECH
Category
Other Electronics
Document type
User Manual
Language
English
Pages
10
File format
PDF
File size
113 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
C87948CE6D656EB9A862B3B87FA5C1ED

About this manual

This manual provides instructions for the Extech 422123 Precision Multifunction Calibrator, a device capable of sourcing mA, mV, V, temperature (°C/°F), and frequency. It details the use of STEP and AUTO RAMP features for current and voltage outputs.

What's inside

  • Meter Description
  • Keypad Function Commands
  • Powering the meter
  • DC Milliamp Outputs
  • DC Voltage Output
  • Temperature Output
  • Frequency Output
  • Programming an Output in Percent
  • Step Mode
  • Automatic Ramp Function

Specifications

DisplayLarge 5 digit multifunction LCD
DC Current Ranges4 to 20.000mA, 0 to 20.000mA, 0 to 24.000mA
DC Voltage Ranges0 to 100.00mV; 0 to 1.0000V; 0 to 12.000V
Power Supply9V battery, external battery pack (6 x 1.5V 'AA'), or optional AC adapter
Operating Conditions32 to 122 o F (0 to 50 o C); 85% RH max.
Dimensions3.46 x 6.61 x 1.03" (88 x 168 x 26mm)

Frequently asked questions

What thermocouple types does the calibrator simulate?

The device simulates Type K, J, E, and T thermocouples.

How long does it take to warm up for optimum accuracy?

The meter must be warmed up for 20 minutes before use for optimum accuracy.

What is the step interval for the Automatic Ramp function?

Each 1% step has a time interval of 0.08 seconds.