RIGOL DSO203 User Manual

DSO203 user manual, including the basic functions, usage methods, maintenance and upgrade of DSO203.


RIGOL DSO203 User Manual - cover page
Brand
Rigol
Document type
User Manual
Language
English
Pages
15
File format
PDF
File size
969 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
33018CEC027000CCC855783D41704DDE

About this manual

The RIGOL DSO203 is a compact 4-channel digital storage oscilloscope designed for electronic engineering tasks. It features an ARM Cortex M3 processor, 72 MS/s sampling rate, and a 3” TFT LCD display. The device includes 2 analog and 2 digital channels, a built-in 2MB USB disk for firmware and waveform storage, and a signal generator. It is powered by rechargeable USB batteries and controlled via 6 buttons and a menu system. The manual covers operation, safety, firmware upgrades, and application examples.

The oscilloscope supports various measurement modes including auto, normal, single, none, and scan. It can display waveforms with cursors, save images, and compare signals. The user interface includes a screen with input, output, and measurement areas, navigated using rocker switches and buttons.

What's inside

  • Introduction
  • Safety
  • Operation Conditions
  • General Inspection
  • Functional Inspection
  • Firmware Upgrade
  • Oscilloscope Operations
  • Interfaces and Buttons
  • Screen Display
  • Application Examples

Specifications

Display3” full color TFT LCD, 400x240 pixels
ADC Bandwidth8 MHz
Sampling Rate72 MS/s
Record Length4096 points
USB Disk2MB
ProcessorARM Cortex M3, STM32VCT6
ADC ConverterAD9288-40 dual A/D converter

Frequently asked questions

How do I upgrade the firmware of the DSO203?

Connect the DSO203 to your PC with a mini USB cable. Hold down the Run button while turning on DSO203. Copy the firmware files one at a time to the USB disk. After each file is copied, disconnect DSO203. When it reconnects, the file will be updated. Upload .hex files first, then .BIN files with corresponding .ADR files. Restart the device to complete the upgrade.

What is the maximum input voltage for the logic probe?

The maximum input voltage of the logic probe is ±15 V peak.

What is the operating temperature range for the DSO203?

The operating temperature range is 0 to +50°C.

What are the available waveforms for the signal generator?

The signal generator can output Square, Sine, Triangle, and Sawtooth waveforms.