This document is the user manual for the ULD-360DMX and ULD-360DMX-HP dimmers produced by Leprecon LLC. It provides information on specifications, installation, operation, and error handling of the products.
The Leprecon ULD-360DMX and ULD-360DMX-HP are portable dimmers designed for temporary and portable dimming requirements, particularly for conventional incandescent fixtures. The ULD-360DMX-HP model features two independent power lines (A and B) to control up to six channels, while the standard ULD-360DMX has a single line. Both models utilize a menu-based interface for configuration and support DMX 512 1990 control.
| Power Connection | 120 VAC 60 Hz |
|---|---|
| Ambient Temperature | less than 40 degrees Celsius |
| Power Capacity (Standard) | 15 Amps |
| Power Capacity (HP) | 30 amps total |
| DMX Standard | DMX 512 1990 |
Depress and hold the ENTER switch while turning on the first breaker.
The default start address is 001.
The available modes are Linear output (Ln), Non-dim (Nd), Florescent output (FL), and Fixed output level.