Agilent LC/MSD TOF Accurate Mass LC/MS Walk-Up Environment Application Note

Accurate mass measurements can be used to both confirm the presence of a compound and help identify unknowns. Obtaining accurate mea- surements using mass spectrometry has typically required highly skilled operators doing interactive instrument operation and data manipula- tion. This Application Note describes how using the Agilent LC/MSD TOF and new software for walk-up operation, chemists can get the accurate mass information they need easily and without much training.


Agilent LC/MSD TOF Accurate Mass LC/MS Walk-Up Environment Application Note - cover page
Brand
Agilent
Category
Other Electronics
Document type
Application Note
Language
English
Pages
8
File format
PDF
File size
823 KB
Published
02 July, 2012
Updated
30 September, 2023
MD5 checksum
2F9722A1DCCB13763E4771C91B3F1FBB

About this manual

Accurate mass measurements are typically performed by skilled operators using interactive instrument operation and data manipulation. This document explains how the Agilent LC/MSD TOF, combined with new software, allows chemists to obtain accurate mass information easily and without extensive training in a walk-up environment.

The Agilent Easy-Access software, adapted from the LC/MSD Quadrupole, simplifies operation by allowing users to log in, input sample information, and select pre-set methods. The system automatically handles calibrant delivery and internal reference mass correction, enabling any operator skilled enough to run a single quadrupole instrument to obtain accurate mass spectra. Users can receive automated reports via email or printout.

What's inside

  • Introduction
  • Submitting samples
  • Obtaining results
  • System status
  • Setup and administration
  • Automated reports

Frequently asked questions

What specific information must a user input when submitting a sample?

The submitter logs in with their name, selects a pre-set method, and inputs the target formula if empirical formula confirmation is desired.

How does the system handle calibration before running new samples?

If enough time has passed since the last run, the system automatically introduces a calibrant mixture and recalculates mass coefficients.

What automated reports can be generated to confirm compound synthesis?

The system produces an Empirical Formula Confirmation report that indicates whether a compound is present based on calculated mass error.