This manual provides information on installation, parameter setting, troubleshooting and maintenance of Delta Electronics' VFD-L series AC motor drives.
This manual provides instructions for installing, configuring, and maintaining Delta's VFD-L series AC motor drives. It includes safety warnings, wiring diagrams, and parameter settings. The document emphasizes proper grounding, avoiding AC power connection to output terminals, and using shielded cables for control circuits. It also details factory settings and operational parameters for different models.
The manual covers various VFD-L models such as VFD002L11A, VFD004L21D, and VFD007L21B, with specific wiring diagrams and parameter tables for each. Safety precautions are highlighted, including disconnecting power before inspection and using appropriate wire gauges. It also explains how to set frequency and voltage ranges, and how to handle motor rotation direction issues. This manual is written in Chinese.
| Maximum Operating Frequency | 50.0 ~ 400Hz |
|---|---|
| Maximum Output Voltage | 2.0 ~ 255V |
| Minimum Output Frequency | 1.0 ~ 60.0Hz |
| Output Frequency Range | 1~400Hz |
No, connecting AC power to output terminals U/T1, V/T2, W/T3 will damage the drive.
The factory setting is 60.0 Hz.
Swap any two of the motor U, V, W terminals to correct the rotation direction.