This manual covers the UNI-T UT136 series handheld digital multimeters, models A, B, C, and D. Functions vary by model: capacitance measurement is only on UT136B, temperature measurement only on UT136C, and NCV only on UT136D. It includes safety precautions, electrical symbols, general specifications, key functions, automatic power-off, and measurement procedures.
Technical specifications include a 4000-count maximum display, 500 V maximum input voltage, 0 to 40 C operating temperature, 72 mm x 137 mm x 35 mm dimensions, about 200 g weight including battery, and a 9 V battery. The manual also lists input impedance, frequency response, fuse protection, and operating limits. This manual is written in Chinese.
| Maximum display | 4000 counts |
|---|---|
| Dimensions | 72 mm x 137 mm x 35 mm |
| Weight | About 200 g including battery |
| Battery | 9 V 6F22 |
| Operating temperature | 0 to 40 C |
| Storage temperature | -10 to 50 C |
| Operating altitude | 0 to 2000 m |
| Maximum input voltage | 500 V DC or AC |
| Input impedance | 10 MΩ on all ranges |
| Frequency response | 40 Hz to 400 Hz |
It indicates that the internal battery is low and should be replaced.
Hold SELECT while turning the meter on, or press a key in sleep mode to wake it; auto power-off is then canceled.
The maximum input voltage is 500 V DC or AC.
Only the UT136D has the NCV function.