Eaton Motor Starter Special Purpose Ratings Application Note

An introduction to the special purpose motor starters and special purpose ratings used in the North American market.


Eaton Motor Starter Special Purpose Ratings Application Note - cover page
Brand
Eaton
Category
Motor
Document type
Application Note
Language
German
Pages
20
File format
PDF
File size
1.7 MB
Published
06 January, 2012
Updated
01 October, 2023
MD5 checksum
B0A3E8B9674569216D77BCC6717D101D

About this manual

This application note clarifies terminology and selection criteria for motor starters in the North American market, specifically focusing on 'Special Purpose Ratings' versus 'General Purpose Ratings'. It details how Eaton Moeller contactors (DIL M, DIL L, and DIL K series) are approved for specific applications under UL and CSA standards, which differ from the universal approach often seen in the IEC world.

The document provides detailed comparison tables mapping North American usage categories (such as AC Elevator Control, AC Refrigeration Control, and AC Resistance Air Heating) to specific horsepower ratings for various voltages. It also distinguishes between motor starters and general-purpose contactors, explaining that while most starters are used for motors, they are dimensioned differently for specialized non-motor loads. This manual is written in German.

What's inside

  • Special Purpose Ratings
  • General Purpose Ratings
  • Motor Starter Combinations
  • UL and CSA Approvals
  • AC Elevator Control
  • AC Refrigeration Control
  • AC Resistance Air Heating
  • Capacitive Switching
  • Incandescent Lamps
  • Eaton Moeller xStart System

Specifications

Applicable Contactor SeriesDIL M, DIL L, DIL K
Voltage Range200 V to 600 V
Frequency60 Hz
Phase Configuration3-pole

Frequently asked questions

Which Eaton contactor series are approved for North American Special Purpose applications?

The DIL M, DIL L, and DIL K series are the UL and CSA approved contactors for these specific applications.

What are the four basic functions of a motor starter?

A motor starter provides disconnecting, short-circuit protection, operational switching, and overload protection.

What switching technology do the largest Eaton Moeller contactors use?

The largest contactors use gas-tight vacuum switching tubes instead of air contacts.

What does the term "General Use" describe?

General Use describes a continuous current that corresponds to the AC-1 current in the IEC world.

Download PDF (1.7 MB)

More Eaton Manuals


View all Eaton manuals →