YASKAWA III series SGM/SGDS Error A.100: Overcurrent or heatsink over‑temperature

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Alarm codeA.100

IGBT generates over‑temperature current or the servo unit's heatsink overheats. The manual's first action is: “DB stop.”

Model
YASKAWA III series SGM/SGDS
Display shows
Overcurrent or heatsink over‑temperature (A.100)
Type
Alarm code
Source
Manual p. 289

What A.100 means

Overcurrent or heatsink over‑temperature p. 289

Common causes

  • IGBT generates over‑temperature current or the servo unit’s heatsink overheats. p. 289
  • Repeated overload‑alarm resets due to power interruptions. p. 289
  • Poor connection between the servo‑unit circuit board and the thermal switch. p. 289
  • Servo‑unit circuit board failure. p. 289
  • Incorrect connection of phases U, V, W and ground. p. 289
  • Ground wire tangled with other terminals. p. 289
  • Short circuit between U, V, W and ground in the motor main‑circuit cable. p. 289
  • Short circuit among U, V, W in the motor main‑circuit cable. p. 289
  • Incorrect wiring of the regeneration resistor. p. 289
  • Short circuit between the servo unit’s U, V, W and ground. p. 289
  • Servo‑unit fault (current‑feedback circuit, power transistor, or circuit board failure). p. 289
  • Short circuit between the servo motor’s U, V, W and ground. p. 289
  • Short circuit among the servo motor’s U, V, W. p. 289
  • DB circuit failure. p. 289
  • Excessive DB usage (DB overload alarm). p. 289
  • Load may be too large or exceed regeneration capacity. p. 289
  • Improper installation of the servo unit (orientation, spacing from other parts), possibly affecting heat dissipation. p. 289
  • Servo‑unit fan has stopped rotating. p. 289
  • Servo‑unit failure. p. 289

What to do

  1. DB stop. p. 289
  2. Change the alarm reset method. p. 289
  3. Replace the servo unit. p. 289
  4. Check wiring and connect correctly. p. 289
  5. Repair or replace the motor main‑circuit cable. p. 289
  6. Replace the servo motor. p. 289
  7. Replace the servo unit (reduce load or lower operating speed). p. 289
  8. Replace the servo unit (reduce DB usage frequency). p. 289
  9. Re‑evaluate load and operating conditions. p. 289
  10. Cool the servo‑unit environment temperature to below 55 °C. p. 289

Before you service the product, read the safety instructions in the manual p. 292.

If A.100 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A.100; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.