YASKAWA III series SGM/SGDS Error A.042: Parameter combination error

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Error codeA.042

The combination of multiple user parameters exceeds the allowed range. The manual's first action is: “DB stop.”

Model
YASKAWA III series SGM/SGDS
Display shows
Parameter combination error (A.042)
Type
Error code
Source
Manual p. 289

What A.042 means

Parameter combination error p. 289

Common causes

  • The combination of multiple user parameters exceeds the allowed range. p. 289
  • Occurs after changing the electronic tooth ratio (Pr20E/Pn210) or installing a servo motor with a different encoder pulse count, then powering on again. p. 289
  • Occurs when the setting for “Program JOG speed (Pr533)” is changed. p. 289
  • Occurs after changing the electronic tooth ratio (Pr20E/Pn210) or installing a servo motor with a different encoder pulse count, then powering on and performing advanced tuning (Fn017). p. 289

What to do

  1. DB stop. p. 289
  2. Decrease the electronic tooth ratio (Pr20E/Pn210). p. 289
  3. Increase the “Program JOG speed (Pr533)” value. p. 289

Before you service the product, read the safety instructions in the manual p. 292.

If A.042 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A.042; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.