Error codeA.042
The combination of multiple user parameters exceeds the allowed range. The manual's first action is: “DB stop.”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- Parameter combination error (A.042)
- Type
- Error code
- Source
- Manual p. 289
What A.042 means
Parameter combination error p. 289
Common causes
- The combination of multiple user parameters exceeds the allowed range. p. 289
- Occurs after changing the electronic tooth ratio (Pr20E/Pn210) or installing a servo motor with a different encoder pulse count, then powering on again. p. 289
- Occurs when the setting for “Program JOG speed (Pr533)” is changed. p. 289
- Occurs after changing the electronic tooth ratio (Pr20E/Pn210) or installing a servo motor with a different encoder pulse count, then powering on and performing advanced tuning (Fn017). p. 289
What to do
- DB stop. p. 289
- Decrease the electronic tooth ratio (Pr20E/Pn210). p. 289
- Increase the “Program JOG speed (Pr533)” value. p. 289
Before you service the product, read the safety instructions in the manual p. 292.
If A.042 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A.042; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.